Literature DB >> 32720169

Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker system.

Biana Dubinsky-Pertzov1, Idan Hecht2, Inbal Gazit2, Lior Or2, Ori Mahler2, Shlomo Rotman2, Eran Pras2, Adi Einan-Lifshitz2.   

Abstract

PURPOSE: To report the clinical outcomes of patients who underwent cataract surgery with implantation of Ankoris monofocal toric intraocular lens (IOL) (PhysIOL SA, Liège, Belgium) using the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA).
METHODS: We conducted a retrospective case series of patients who underwent routine cataract extraction and implantation of Ankoris toric IOL using the Zeiss Callisto eye between January 2018 and December 2018 by four senior surgeons. Patients' medical records were reviewed, and clinical outcomes including postoperative refraction, visual acuity outcomes, IOL position and deviation from planned axis were collected.
RESULTS: Fifty-six eyes of 56 patients were included, 48% were female, and the mean age was 70 ± 8 years. Patients with pseudoexfoliation syndrome, glaucoma or keratoconus were excluded from the study. Pre-operative mean corneal astigmatism was 2.38 ± 0.78 diopters (D), and mean implanted IOL cylindrical power was 3.06 ± 1.07 D. IOL rotation 30 days postoperatively was within 5° in 82% of eyes and between 6° and 10° in 10.8% of eyes. Mean postoperative refractive astigmatism 30 days postoperatively was 0.22 ± 0.36 D; in 84% of eyes the postoperative refractive astigmatism was ≤ 0.50 D. IOL rotation significantly increased between day 1 to day 7 postoperatively (1.91 ± 3.15° to 3.18 ± 3.3°, P = 0.001). However, no significant rotation had occurred between day 7 and day 30 postoperatively (P = 0.093).
CONCLUSION: Cataract surgery with implantation of Ankoris monofocal toric IOL using the Zeiss Callisto Eye marking system is predictable and effective in reducing refractive astigmatism.

Entities:  

Keywords:  Astigmatism; Cataract; IOL; IOL rotation; Toric IOL

Mesh:

Year:  2020        PMID: 32720169     DOI: 10.1007/s10792-020-01511-4

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  24 in total

1.  Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam.

Authors:  Clare O'Donnell; Carole Maldonado-Codina
Journal:  Cornea       Date:  2005-11       Impact factor: 2.651

2.  [Prevalence and age-related changes of corneal astigmatism in patients before cataract surgery].

Authors:  M Michelitsch; N Ardjomand; B Vidic; A Wedrich; G Steinwender
Journal:  Ophthalmologe       Date:  2017-03       Impact factor: 1.059

3.  Rotational Stability of Monofocal and Trifocal Intraocular Toric Lenses With Identical Design and Material but Different Surface Treatment.

Authors:  Kristof Vandekerckhove
Journal:  J Refract Surg       Date:  2018-02-01       Impact factor: 3.573

Review 4.  Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking.

Authors:  Fengqi Zhou; Wu Jiang; Zhuoling Lin; Xiaoyan Li; Jing Li; Haotian Lin; Weirong Chen; Qiwei Wang
Journal:  J Cataract Refract Surg       Date:  2019-09       Impact factor: 3.351

5.  Comparison of the Rotational Stability of Two Toric Intraocular Lenses in 1273 Consecutive Eyes.

Authors:  Bryan S Lee; David F Chang
Journal:  Ophthalmology       Date:  2018-03-12       Impact factor: 12.079

6.  Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results.

Authors:  Warren Hill
Journal:  J Cataract Refract Surg       Date:  2008-03       Impact factor: 3.351

7.  Prevalence of corneal astigmatism before cataract surgery.

Authors:  Teresa Ferrer-Blasco; Robert Montés-Micó; Sofia C Peixoto-de-Matos; José M González-Méijome; Alejandro Cerviño
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

8.  Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation.

Authors:  Wolfgang J Mayer; Thomas Kreutzer; Martin Dirisamer; Christoph Kern; Karsten Kortuem; Efstathios Vounotrypidis; Siegfried Priglinger; Daniel Kook
Journal:  J Cataract Refract Surg       Date:  2017-10-19       Impact factor: 3.351

Review 9.  Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis.

Authors:  Line Kessel; Jens Andresen; Britta Tendal; Ditte Erngaard; Per Flesner; Jesper Hjortdal
Journal:  Ophthalmology       Date:  2015-11-18       Impact factor: 12.079

10.  Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: Suggested terminology, analysis, and standards for outcome reports.

Authors:  Adi Abulafia; Douglas D Koch; Jack T Holladay; Li Wang; Warren Hill
Journal:  J Cataract Refract Surg       Date:  2018-10       Impact factor: 3.351

View more
  2 in total

1.  Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism.

Authors:  Merve Bozkurt Gencer; Hikmet Basmak; Erdogan Yasar; Ozkan Onal
Journal:  Int J Ophthalmol       Date:  2021-12-18       Impact factor: 1.779

Review 2.  Toric intraocular lenses: Expanding indications and preoperative and surgical considerations to improve outcomes.

Authors:  Vivek Mahendrapratap Singh; Muralidhar Ramappa; Somasheila I Murthy; Audrey Talley Rostov
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

  2 in total