Literature DB >> 12765888

Closed-loop control of propofol anaesthesia using bispectral index: performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanil infusions for minor surgery.

A R Absalom1, G N C Kenny.   

Abstract

BACKGROUND: In a previous study we used the bispectral index (BIS) for automatic control of propofol anaesthesia, using a proportional-integral-differential control algorithm. As control was less than optimal in some patients, we revised the constants of the control algorithm. The aim of the current study was to measure the performance of the revised system in patients undergoing minor surgery under propofol and remifentanil anaesthesia.
METHODS: Twenty adult patients scheduled for body surface surgery were enrolled. Anaesthesia was manually induced with target-controlled infusions (TCI) of propofol and remifentanil. After the start of surgery, when anaesthesia was clinically adequate, automatic control of the propofol TCI was commenced using the revised closed-loop system. For patients 11-20, effect-site steering was also incorporated into the closed-loop control algorithm. Adequacy of anaesthesia during closed-loop control was assessed clinically, and by calculating the median performance error (MDPE), the median absolute performance error (MDAPE) and the mean offset of the control variable.
RESULTS: The system provided adequate operating conditions and stable cardiovascular values in all patients during closed-loop control. The mean MDPE and MDAPE were -0.42% and 5.63%, respectively. Mean offset of the BIS from setpoint was -0.2. No patients reported awareness or recall of intraoperative events.
CONCLUSIONS: The system was able to provide clinically adequate anaesthesia in all patients, with better accuracy of control than in the previous study. There was a tendency for more accurate control in those patients in whom the control algorithm incorporated effect-site steering.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12765888     DOI: 10.1093/bja/aeg137

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  14 in total

1.  Closed-Loop Intravenous Drug Administration Using Photoplethysmography.

Authors:  George W Carpenter; Holly G Myers; Eric A Sherer; Katie A Evans; D Patrick O'Neal
Journal:  IEEE J Transl Eng Health Med       Date:  2018-11-01       Impact factor: 3.316

2.  Dynamic behavior of BIS, M-entropy and neuroSENSE brain function monitors.

Authors:  Stéphane Bibian; Guy A Dumont; Tatjana Zikov
Journal:  J Clin Monit Comput       Date:  2010-12-05       Impact factor: 2.502

3.  Predictive performance of 'Diprifusor' TCI system in patients during upper abdominal surgery under propofol/fentanyl anesthesia.

Authors:  Yu-hong Li; Jian-hong Xu; Jian-jun Yang; Jie Tian; Jian-guo Xu
Journal:  J Zhejiang Univ Sci B       Date:  2005-01       Impact factor: 3.066

4.  An Adaptive Monitoring Scheme for Automatic Control of Anaesthesia in dynamic surgical environments based on Bispectral Index and Blood Pressure.

Authors:  Yu-Ning Yu; Faiyaz Doctor; Shou-Zen Fan; Jiann-Shing Shieh
Journal:  J Med Syst       Date:  2018-04-13       Impact factor: 4.460

Review 5.  The Role of GABA Receptor Agonists in Anesthesia and Sedation.

Authors:  Janette Brohan; Basavana G Goudra
Journal:  CNS Drugs       Date:  2017-10       Impact factor: 5.749

6.  A closed-loop anesthetic delivery system for real-time control of burst suppression.

Authors:  Max Y Liberman; Shinung Ching; Jessica Chemali; Emery N Brown
Journal:  J Neural Eng       Date:  2013-06-07       Impact factor: 5.379

7.  Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

Authors:  Corinne Dussaussoy; Marine Peres; Virginie Jaoul; Ngai Liu; Thierry Chazot; Jean Picquet; Marc Fischler; Laurent Beydon
Journal:  J Clin Monit Comput       Date:  2013-03-15       Impact factor: 2.502

8.  Real-time closed-loop control in a rodent model of medically induced coma using burst suppression.

Authors:  ShiNung Ching; Max Y Liberman; Jessica J Chemali; M Brandon Westover; Jonathan D Kenny; Ken Solt; Patrick L Purdon; Emery N Brown
Journal:  Anesthesiology       Date:  2013-10       Impact factor: 7.892

9.  IMPROVED TRANSFORMATION OF MORPHOMETRIC MEASUREMENTS FOR A PRIORI PARAMETER ESTIMATION IN A PHYSIOLOGICALLY-BASED PHARMACOKINETIC MODEL OF ETHANOL.

Authors:  Martin H Plawecki; Ray Decarlo; Vijay A Ramchandani; Sean O'Connor
Journal:  Biomed Signal Process Control       Date:  2007-04       Impact factor: 3.880

10.  Feedback control for clinicians.

Authors:  Guy A Dumont
Journal:  J Clin Monit Comput       Date:  2013-04-12       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.