Literature DB >> 29654373

An Adaptive Monitoring Scheme for Automatic Control of Anaesthesia in dynamic surgical environments based on Bispectral Index and Blood Pressure.

Yu-Ning Yu1, Faiyaz Doctor2, Shou-Zen Fan3, Jiann-Shing Shieh4.   

Abstract

During surgical procedures, bispectral index (BIS) is a well-known measure used to determine the patient's depth of anesthesia (DOA). However, BIS readings can be subject to interference from many factors during surgery, and other parameters such as blood pressure (BP) and heart rate (HR) can provide more stable indicators. However, anesthesiologist still consider BIS as a primary measure to determine if the patient is correctly anaesthetized while relaying on the other physiological parameters to monitor and ensure the patient's status is maintained. The automatic control of administering anesthesia using intelligent control systems has been the subject of recent research in order to alleviate the burden on the anesthetist to manually adjust drug dosage in response physiological changes for sustaining DOA. A system proposed for the automatic control of anesthesia based on type-2 Self Organizing Fuzzy Logic Controllers (T2-SOFLCs) has been shown to be effective in the control of DOA under simulated scenarios while contending with uncertainties due to signal noise and dynamic changes in pharmacodynamics (PD) and pharmacokinetic (PK) effects of the drug on the body. This study considers both BIS and BP as part of an adaptive automatic control scheme, which can adjust to the monitoring of either parameter in response to changes in the availability and reliability of BIS signals during surgery. The simulation of different control schemes using BIS data obtained during real surgical procedures to emulate noise and interference factors have been conducted. The use of either or both combined parameters for controlling the delivery Propofol to maintain safe target set points for DOA are evaluated. The results show that combing BIS and BP based on the proposed adaptive control scheme can ensure the target set points and the correct amount of drug in the body is maintained even with the intermittent loss of BIS signal that could otherwise disrupt an automated control system.

Entities:  

Keywords:  Anesthesia; Bispectral index; Blood pressure; Depth of anesthesia; Pharmacodynamics and pharmacokinetic; Propofol; Type-2 Self Organizing Fuzzy Logic Controllers

Mesh:

Year:  2018        PMID: 29654373     DOI: 10.1007/s10916-018-0933-6

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  25 in total

1.  A randomized double-blinded comparison of phenylephrine and ephedrine infusion combinations to maintain blood pressure during spinal anesthesia for cesarean delivery: the effects on fetal acid-base status and hemodynamic control.

Authors:  Warwick D Ngan Kee; Anna Lee; Kim S Khaw; Floria F Ng; Manoj K Karmakar; Tony Gin
Journal:  Anesth Analg       Date:  2008-10       Impact factor: 5.108

2.  Self-learning fuzzy logic control of neuromuscular block.

Authors:  J J Ross; D G Mason; D A Linkens; N D Edwards
Journal:  Br J Anaesth       Date:  1997-04       Impact factor: 9.166

3.  Self-learning fuzzy control of atracurium-induced neuromuscular block during surgery.

Authors:  D G Mason; J J Ross; N D Edwards; D A Linkens; C S Reilly
Journal:  Med Biol Eng Comput       Date:  1997-09       Impact factor: 2.602

4.  Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.

Authors:  M M Struys; T De Smet; L F Versichelen; S Van De Velde; R Van den Broecke; E P Mortier
Journal:  Anesthesiology       Date:  2001-07       Impact factor: 7.892

Review 5.  Consciousness and anesthesia.

Authors:  Michael T Alkire; Anthony G Hudetz; Giulio Tononi
Journal:  Science       Date:  2008-11-07       Impact factor: 47.728

6.  Performance evaluation of two published closed-loop control systems using bispectral index monitoring: a simulation study.

Authors:  Michel M R F Struys; Tom De Smet; Scott Greenwald; Anthony R Absalom; Servaas Bingé; Eric P Mortier
Journal:  Anesthesiology       Date:  2004-03       Impact factor: 7.892

7.  Simultaneous electroencephalography and functional magnetic resonance imaging of general anesthesia.

Authors:  Patrick L Purdon; Eric T Pierce; Giorgio Bonmassar; John Walsh; P Grace Harrell; Jean Kwo; Daniel Deschler; Margaret Barlow; Rebecca C Merhar; Camilo Lamus; Catherine M Mullaly; Mary Sullivan; Sharon Maginnis; Debra Skoniecki; Helen-Anne Higgins; Emery N Brown
Journal:  Ann N Y Acad Sci       Date:  2009-03       Impact factor: 5.691

8.  Simultaneous modeling of pharmacokinetics and pharmacodynamics: application to d-tubocurarine.

Authors:  L B Sheiner; D R Stanski; S Vozeh; R D Miller; J Ham
Journal:  Clin Pharmacol Ther       Date:  1979-03       Impact factor: 6.875

Review 9.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

10.  Performance analysis of extracted rule-base multivariable type-2 self-organizing fuzzy logic controller applied to anesthesia.

Authors:  Yan-Xin Liu; Faiyaz Doctor; Shou-Zen Fan; Jiann-Shing Shieh
Journal:  Biomed Res Int       Date:  2014-12-21       Impact factor: 3.411

View more
  2 in total

1.  Control strategy with multivariable fault tolerance module for automatic intravenous anesthesia.

Authors:  Bhavina Patel; Hirenkumar Patel; Divyang Shah; Alpesh Sarvaia
Journal:  Biomed Eng Lett       Date:  2020-08-16

Review 2.  Intelligent automated drug administration and therapy: future of healthcare.

Authors:  Richa Sharma; Dhirendra Singh; Prerna Gaur; Deepak Joshi
Journal:  Drug Deliv Transl Res       Date:  2021-01-14       Impact factor: 4.617

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.