Literature DB >> 12765329

Intraoperative dynamic dosimetry for prostate implants.

D A Todor1, M Zaider, G N Cohen, M F Worman, M J Zelefsky.   

Abstract

This paper describes analytic tools in support of a paradigm shift in brachytherapy treatment planning for prostate cancer--a shift from standard pre-planning to intraoperative planning using dosimetric feedback based on the actual deposited seed positions within the prostate. The method proposed is guided by several desiderata: (a) bringing both planning and evaluation in the operating room (i.e. make post-implant evaluation superfluous) therefore making rectifications--if necessary--still achievable; (b) making planning and implant evaluation consistent by using the same imaging system (ultrasound); and (c) using only equipment commonly found in a hospital operating room. The intraoperative dosimetric evaluation is based on the fusion between ultrasound images and 3D seed coordinates reconstructed from fluoroscopic projections. Automatic seed detection and registration of the fluoroscopic and ultrasound information, two of the three key ingredients needed for the intraoperative dynamic dosimetry optimization (IDDO), are explained in detail. The third one, the reconstruction of 3D coordinates from projections, was reported in a previous article. The algorithms were validated using a custom-designed phantom with non-radioactive (dummy) seeds. Also, fluoroscopic images were taken at the conclusion of an actual permanent prostate implant and compared with data on the same patient obtained from radiographic-based post-implant evaluation. To offset the effect of organ motion the comparison was performed in terms of the proximity function of the two seed distributions. The agreement between the intra- and post-operative seed distributions was excellent.

Entities:  

Mesh:

Year:  2003        PMID: 12765329     DOI: 10.1088/0031-9155/48/9/306

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  INTENSITY-BASED REGISTRATION OF PROSTATE BRACHYTHERAPY IMPLANTS AND ULTRASOUND.

Authors:  Z Karimaghaloo; G Fichtinger; D G Gobbi; E C Burdette; R N Rohling; P Abolmaesumi
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-06-13

2.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

3.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Omar Y Mian; Yi Le; E Clif Burdette; Gabor Fichtinger; Jerry L Prince; Danny Y Song; Junghoon Lee
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

Review 5.  Recent developments and best practice in brachytherapy treatment planning.

Authors:  C D Lee
Journal:  Br J Radiol       Date:  2014-06-02       Impact factor: 3.039

6.  REDUCED-DIMENSIONALITY MATCHING FOR 3-D RECONSTRUCTION OF PROSTATE BRACHYTHERAPY IMPLANTS FROM INCOMPLETE DATA.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Gabor Fichtinger; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-06-28

7.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

8.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

9.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048

10.  Radiation safety of receptive anal intercourse with prostate cancer patients treated with low-dose-rate brachytherapy.

Authors:  Nicola J Nasser; Gil'ad N Cohen; Lawrence T Dauer; Michael J Zelefsky
Journal:  Brachytherapy       Date:  2016-05-12       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.