Literature DB >> 12763446

Effect of consolidation on adhesive and abrasive wear of ultra high molecular weight polyethylene.

Rizwan M Gul1, Frederick J McGarry, Charles R Bragdon, Orhun K Muratoglu, William H Harris.   

Abstract

Total hip replacement (THR) is widely performed to recover hip joint functions lost by trauma or disease and to relieve pain. The major cause of failure in THR is the wear of the ultra high molecular weight polyethylene (UHMWPE) component. The dominant wear mechanism in THR occurs through adhesion and abrasion. While poor consolidation of UHMWPE is known to increase the incidence of a different damage mode, delamination, which is the dominant wear mechanism in tibial inserts but uncommon in THR, the effect of consolidation on adhesive and abrasive wear of UHMWPE is not clear. In this study UHMWPE resin was subjected to hot isostatic pressing under a pressure of 138MPa at different temperatures (210 degrees C, 250 degrees C, and 300 degrees C) to achieve varying degrees of consolidation. The extent of consolidation was determined by optical microscopy using thin sections, and by scanning electron microscopy using cryofractured and solvent etched specimens. Wear behavior of the samples with varying degree of consolidation was determined using a bi-directional pin-on-disc machine simulating conditions in a hip joint. Increasing the processing temperature decreased the incidence of fusion defects and particle boundaries reflecting the powder flakes of the virgin resin, improving the consolidation. However, the bi-directional pin-on-disc wear rate did not change with the processing temperature, indicating that adhesive and abrasive wear is independent of the extent of consolidation in the range of parameters studied here.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12763446     DOI: 10.1016/s0142-9612(03)00165-0

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  In vivo oxidation contributes to delamination but not pitting in polyethylene components for total knee arthroplasty.

Authors:  Francisco J Medel; Steven M Kurtz; Javad Parvizi; Gregg R Klein; Matthew J Kraay; Clare M Rimnac
Journal:  J Arthroplasty       Date:  2010-09-28       Impact factor: 4.757

2.  Gamma inert sterilization: a solution to polyethylene oxidation?

Authors:  Francisco J Medel; Steven M Kurtz; William J Hozack; Javad Parvizi; James J Purtill; Peter F Sharkey; Daniel MacDonald; Matthew J Kraay; Victor Goldberg; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

Review 3.  Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers.

Authors:  D Baykal; R S Siskey; H Haider; V Saikko; T Ahlroos; S M Kurtz
Journal:  J Mech Behav Biomed Mater       Date:  2013-05-29

4.  The effects of peroxide content on the wear behavior, microstructure and mechanical properties of peroxide crosslinked ultra-high molecular weight polyethylene used in total hip replacement.

Authors:  Rizwan M Gul
Journal:  J Mater Sci Mater Med       Date:  2008-01-25       Impact factor: 3.896

5.  Significance of nano- and microtopography for cell-surface interactions in orthopaedic implants.

Authors:  M Jäger; C Zilkens; K Zanger; R Krauspe
Journal:  J Biomed Biotechnol       Date:  2007
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.