Literature DB >> 12760934

Multidetector CT angiography for preoperative evaluation of living laparoscopic kidney donors.

Satomi Kawamoto1, Robert A Montgomery, Leo P Lawler, Karen M Horton, Elliot K Fishman.   

Abstract

OBJECTIVE: The purpose of this study was to determine the accuracy of multidetector CT (MDCT) angiography as the primary imaging technique in the evaluation of living kidney donors. SUBJECTS AND METHODS: Seventy-four consecutive living kidney donors (30 men, 44 women; mean age, 41.7 years) who underwent MDCT were evaluated. CT examination was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec and a pitch of 6. In every case, arterial and venous phase volumetric data sets were acquired at 25 and 55 sec, respectively. Scans were reconstructed at 1-mm intervals for three-dimensional (3D) imaging using a volume-rendering technique. Axial CT images and 3D CT angiography were evaluated prospectively by one reviewer and retrospectively by two reviewers who had no knowledge of surgical results. Surgical correlation for the location of primary and accessory renal arteries, early branching of the renal arteries, and renal vein anomalies was made.
RESULTS: Seventy-two subjects underwent left nephrectomy, and two subjects underwent right nephrectomy because supernumerary left renal arteries were detected on preoperative CT angiography. Eighteen supernumerary renal arteries (two arteries to 16 kidneys and three arteries to one kidney) to 74 kidneys underwent nephrectomy. CT and surgical findings agreed in 93% of subjects (the average of three reviewers; range, 89-97%). Two small accessory renal arteries were missed by all three reviewers. Those arteries were diminutive and were thought to be insignificant by the surgeons. Early branching of the renal arteries was shown in 14 arteries, and CT and surgical findings agreed in 96% (the average of three reviewers; range, 93-97%). Renal vein anomalies were present in eight subjects, and CT and surgical findings agreed in 99% of the cases (range, 96-100%).
CONCLUSION: MDCT angiography is highly accurate for detecting vascular anomalies and providing anatomic information for laparoscopic living donor nephrectomy.

Entities:  

Mesh:

Year:  2003        PMID: 12760934     DOI: 10.2214/ajr.180.6.1801633

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  24 in total

1.  Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors.

Authors:  Masatomo Kuwabara; Yoshifumi Narumi; Satoru Takahashi; Yoshinobu Sato; Tonsok Kim; Takamichi Murakami; Hironobu Nakamura
Journal:  Radiat Med       Date:  2006-04

2.  Anatomic variations of the hepatic arteries in 250 patients studied with 64-row CT angiography.

Authors:  Carlo Nicola De Cecco; Riccardo Ferrari; Marco Rengo; Pasquale Paolantonio; Fabrizio Vecchietti; Andrea Laghi
Journal:  Eur Radiol       Date:  2009-05-27       Impact factor: 5.315

3.  A simple method to estimate renal volume from computed tomography.

Authors:  Rodney H Breau; Edward Clark; Bryan Bruner; Patrick Cervini; Thomas Atwell; Greg Knoll; Bradley C Leibovich
Journal:  Can Urol Assoc J       Date:  2013 May-Jun       Impact factor: 1.862

Review 4.  Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications.

Authors:  Uei Pua; Cher Heng Tan; Hee Hwa Ho; Julian Ko Beng Tan; Paul Jau Leong Ong
Journal:  Eur Radiol       Date:  2014-08-28       Impact factor: 5.315

5.  Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

Authors:  Sung Yoon Park; Chan Kyo Kim; EunJu Kim; Byung Kwan Park
Journal:  Eur Radiol       Date:  2014-09-13       Impact factor: 5.315

6.  Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.

Authors:  Woong Kyu Han; Joon Chae Na; Sung Yoon Park
Journal:  Eur Radiol       Date:  2019-08-30       Impact factor: 5.315

7.  Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

Authors:  Aysel Türkvatan; Serkan Akinci; Sener Yildiz; Tülay Olçer; Turhan Cumhur
Journal:  Surg Radiol Anat       Date:  2008-10-25       Impact factor: 1.246

8.  Prevalence of renal artery and kidney abnormalities by computed tomography among healthy adults.

Authors:  Elizabeth C Lorenz; Terri J Vrtiska; John C Lieske; John J Dillon; Mark D Stegall; Xujian Li; Eric J Bergstralh; Andrew D Rule
Journal:  Clin J Am Soc Nephrol       Date:  2010-01-14       Impact factor: 8.237

9.  Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.

Authors:  Woong Yoon; Min Young Lee; Jung Min Ryu; Yong Ju Moon; Sang Hun Lee; Jae Hong Park; Seung Pil Yun; Min Woo Jang; Sung Su Park; Ho Jae Han
Journal:  J Vet Sci       Date:  2010-03       Impact factor: 1.672

10.  Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

Authors:  Shingo Yamamoto; Masao Tanooka; Kumiko Ando; Toshiko Yamano; Reiichi Ishikura; Michio Nojima; Shozo Hirota; Hiroki Shima
Journal:  Int Urol Nephrol       Date:  2009-03-06       Impact factor: 2.370

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.