Image resolution of the Lunar Expert-XL.

J A Thorpe1, S A Steel.   

Abstract

The Lunar Expert-XL is an example of the latest generation of fan beam densitometers, with the X-ray source and detector array mounted on a C-arm to enable supine lateral imaging. Image resolution for anteroposterior (AP) spine, femur, hand, forearm and lateral morphometry on the Expert-XL were assessed in vitro with the 07-541 Nuclear Associates line pair test pattern. Each scan type was investigated at all available tube currents and scan speeds, and at the maximum, minimum and default bed heights. The effect of soft tissue thickness on resolution was investigated by using varying amounts of Perspex attenuator. The in vitro median lateral (x-axis) resolutions at the default bed height for the default scan types were 0.9 line pairs (lps)/mm for the 5 mA fast AP spine and femur scans, and l.0 lps/mm for 1 mA fast hand, forearm and 5 mA fast morphometry scans. This equates to a resolution of about 1 mm. The best resolution achieved was 1.2 lps/mm (0.83 mm), obtainable on all scan modes with the bed at maximum elevation, but only consistently with the forearm mode. Lower tube current did not affect resolution but did change the range of soft tissue thickness over which an image could be resolved. Turbo scan modes greatly reduced longitudinal (y-axis) resolution but had little effect on lateral resolution. This study demonstrates the importance of including an assessment of resolution when validating new equipment, especially if morphometric investigations are to be conducted.

Entities:  

Mesh:

Year:  1999        PMID: 10501787     DOI: 10.1007/s001980050201

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  3 in total

1.  The effect of room temperature on dual-energy X-ray absorptiometry.

Authors:  N L Culton; N A Pocock
Journal:  Osteoporos Int       Date:  2003-03-04       Impact factor: 4.507

2.  Image resolution and magnification using a cone beam densitometer: optimizing data acquisition for hip morphometric analysis.

Authors:  V Boudousq; D Mariano Goulart; J M Dinten; C Caderas de Kerleau; E Thomas; O Mares; P O Kotzki
Journal:  Osteoporos Int       Date:  2004-10-16       Impact factor: 4.507

3.  Body Segment Inertial Parameters of elite swimmers Using DXA and indirect Methods.

Authors:  Marcel Rossi; Andrew Lyttle; Amar El-Sallam; Nat Benjanuvatra; Brian Blanksby
Journal:  J Sports Sci Med       Date:  2013-12-01       Impact factor: 2.988

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.