Axial and total-body bone densitometry using a narrow-angle fan-beam.

R B Mazess1, J A Hanson, R Payne, R Nord, M Wilson.   

Abstract

We assessed a new dual-energy bone densitometer, the PRODIGY, that uses a narrow-angle fan-beam (4.5 degrees) oriented parallel to the longitudinal axis of the body (i.e., perpendicular to the usual orientation). High-resolution scans across the body can be stepped at 17 mm intervals. The energy-sensitive array detector uses cadmium zinc telluride, which allowed rapid photon counting. Spine and femur scans required 30 s, and total-body scans required 4-5 min; the dose was only 3.7 mrem and 0.04 mrem respectively, or about 5 to 10 times lower than conventional fan-beam densitometry. We found only a small influence of soft-tissue thickness on bone mineral density (BMD) results. There was also a small (+/- 1%) influence of height above the tabletop on BMD results. A software correction for object height allowed a first-order correction for the large magnification effects of position on bone mineral content (BMC) and area. Consequently, the results for BMC and area, as well as BMD, with PRODIGY corresponded closely to those obtained using the predecessor DPX densitometer, both in vitro and in vivo; there was a generally high correlation (r = 0.98-0.99) for BMD values. Spine and femur values for BMC, area and BMD averaged within 0.5% in vivo (n = 122), as did total-body BMC and BMD (n = 46). PRODIGY values for total-body lean tissue and fat also corresponded within 1% to DPX values. Regional and total-body BMD were measured with 0.5% precision in vitro and 1% precision in vivo. The new PRODIGY densitometer appears to combine the low dose and high accuracy of pencil-beam densitometry with the speed of fan-beam densitometers.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  2000        PMID: 10793875     DOI: 10.1007/PL00004178

Source DB:  PubMed          Journal:  Osteoporos Int        ISSN: 0937-941X            Impact factor:   4.507


  15 in total

1.  The effect of room temperature on dual-energy X-ray absorptiometry.

Authors:  N L Culton; N A Pocock
Journal:  Osteoporos Int       Date:  2003-03-04       Impact factor: 4.507

2.  Validity of anthropometric measurements for characterizing obesity among adult survivors of childhood cancer: A report from the St. Jude Lifetime Cohort Study.

Authors:  Robyn E Karlage; Carmen L Wilson; Nan Zhang; Sue Kaste; Daniel M Green; Gregory T Armstrong; Leslie L Robison; Wassim Chemaitilly; Deo Kumar Srivastava; Melissa M Hudson; Kirsten K Ness
Journal:  Cancer       Date:  2015-02-27       Impact factor: 6.860

3.  Image resolution and magnification using a cone beam densitometer: optimizing data acquisition for hip morphometric analysis.

Authors:  V Boudousq; D Mariano Goulart; J M Dinten; C Caderas de Kerleau; E Thomas; O Mares; P O Kotzki
Journal:  Osteoporos Int       Date:  2004-10-16       Impact factor: 4.507

4.  Pediatric in vivo cross-calibration between the GE Lunar Prodigy and DPX-L bone densitometers.

Authors:  Nicola J Crabtree; N J Shaw; C M Boivin; B Oldroyd; J G Truscott
Journal:  Osteoporos Int       Date:  2005-10-19       Impact factor: 4.507

5.  Bone mineral content, corrected for height or bone area, measured by DXA is not reduced in children with chronic renal disease or in hypoparathyroidism.

Authors:  S Faisal Ahmed; Shiuli Russell; Rajeeb Rashid; T James Beattie; Anna V Murphy; Ian J Ramage; Heather Maxwell
Journal:  Pediatr Nephrol       Date:  2005-07-27       Impact factor: 3.714

6.  Bone measures in HIV-1 infected children and adolescents: disparity between quantitative computed tomography and dual-energy X-ray absorptiometry measurements.

Authors:  Pisit Pitukcheewanont; David Safani; Joseph Church; Vicente Gilsanz
Journal:  Osteoporos Int       Date:  2005-02-09       Impact factor: 4.507

7.  Total dose incurred by patients and staff from BMD measurement using a new 2D digital bone densitometer.

Authors:  V Boudousq; P O Kotzki; J M Dinten; C Barrau; C Robert-Coutant; E Thomas; D Mariano Goulart
Journal:  Osteoporos Int       Date:  2003-04-01       Impact factor: 4.507

8.  Assessment of bone mineral density by dual x-ray absorptiometry in dermatological patients treated by corticosteroids.

Authors:  Dorria Salem; Soha Talaat; Mona R E Abdel-Halim; Kareem Mohammed Mohsen
Journal:  Indian J Dermatol       Date:  2010 Jul-Sep       Impact factor: 1.494

9.  Pediatric radiation dose and risk from bone density measurements using a GE Lunar Prodigy scanner.

Authors:  J Damilakis; G Solomou; G E Manios; A Karantanas
Journal:  Osteoporos Int       Date:  2013-01-10       Impact factor: 4.507

10.  Cohort profile: The men androgen inflammation lifestyle environment and stress (MAILES) study.

Authors:  Janet F Grant; Sean A Martin; Anne W Taylor; David H Wilson; Andre Araujo; Robert J T Adams; Alicia Jenkins; Robert W Milne; Graeme J Hugo; Evan Atlantis; Gary A Wittert
Journal:  Int J Epidemiol       Date:  2013-06-19       Impact factor: 7.196

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.