Carotid stenting with filter protection. Correlation of ACT values with angiographic and histopathologic findings.

L Castellan1, F Causin, D Danieli, S Perini.   

Abstract

BACKGROUND AND
PURPOSE: Filter cerebral protection during carotid stenting has been proposed as a new tool to reduce brain embolism. Angiographic findings (filter patency), pathological analysis of the collected materials inside the filters and coagulation parameters were analyzed to identify potential down sides in the use of these protection devices.
METHODS: 29 consecutive endovascular treatments with filter cerebral protection in 27 patients affected by symptomatic internal carotid stenosis>70% were considered. Angiographic findings, activated clotting times and histopathologic specimens were recorded and correlated.
RESULTS: Satisfactory dilatation of the stenosis was always achieved with a complication rate of 3% (1 transient neurological deficit). During the procedure, 9 filters (31%) appeared occluded, with temporary flow impairment. Histopathologic examination demonstrated material inside the filters in 86% of cases but this material was fibrin alone in 38% and plaque debris in 48%. Significant statistical correlation (p=0.009) was found between low activated clotting time and occlusion of the filter.
CONCLUSION: Distal protection filters can collect plaque fragments occurring during carotid stenting. Significant proportion of the debris found in the filters consisted of thrombotic material. Precise monitoring of heparin anticoagulation is recommended to prevent filter occlusion.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12717296

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  9 in total

1.  Computational modeling of distal protection filters.

Authors:  Gail M Siewiorek; Ender A Finol
Journal:  J Endovasc Ther       Date:  2010-12       Impact factor: 3.487

2.  Diffusion-weighted MR imaging lesions after filter-protected stenting of high-grade symptomatic carotid artery stenoses.

Authors:  R du Mesnil de Rochemont; S Schneider; B Yan; A Lehr; M Sitzer; J Berkefeld
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

3.  Recanalization of acute carotid stent occlusion using Penumbra 4Max aspiration catheter: technical report and review of rescue strategies for acute carotid stent occlusion.

Authors:  Stephan Munich; Roham Moftakhar; Demetrius Lopes
Journal:  BMJ Case Rep       Date:  2013-10-14

Review 4.  Point-of-care testing for anticoagulation monitoring in neuroendovascular procedures.

Authors:  H M Hussein; A L Georgiadis; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-15       Impact factor: 3.825

5.  Clinical implications of internal carotid artery flow impairment caused by filter occlusion during carotid artery stenting.

Authors:  O-K Kwon; S H Kim; E A Jacobsen; M P Marks
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-15       Impact factor: 3.825

6.  Monitoring of the heparinization in the rabbit animal model during endovascular interventions.

Authors:  Anne J Schmitt; Anna K Wallner; Shahrzad Afazel; Monika Killer-Oberpfalzer
Journal:  Neuroradiology       Date:  2013-04-26       Impact factor: 2.804

7.  Initial experience of using the filter protection device during carotid artery stenting in Japan.

Authors:  Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Toshiteru Miyasaka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Ichiro Nakagawa; Shinichiro Kurokawa; Kimihiko Kichikawa
Journal:  Radiat Med       Date:  2008-08-03

Review 8.  Carotid artery stenting versus carotid endarterectomy: systematic review and meta-analysis.

Authors:  Zhenjie Liu; Zhenyu Shi; Yuqi Wang; Bin Chen; Ting Zhu; Yi Si; Weiguo Fu
Journal:  World J Surg       Date:  2009-03       Impact factor: 3.352

9.  Cerebral ischemia detected with diffusion-weighted MR imaging after protected carotid artery stenting: comparison of distal balloon and filter device.

Authors:  Suk Jung Kim; Hong Gee Roh; Pyoung Jeon; Keon Ha Kim; Kwang Ho Lee; Hong Sik Byun; Won Jin Moon; Gyeong Moon Kim; Young Wook Kim; Dong Ik Kim
Journal:  Korean J Radiol       Date:  2007 Jul-Aug       Impact factor: 3.500

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.