Literature DB >> 22173773

Clinical implications of internal carotid artery flow impairment caused by filter occlusion during carotid artery stenting.

O-K Kwon1, S H Kim, E A Jacobsen, M P Marks.   

Abstract

BACKGROUND AND
PURPOSE: Membrane filters are EPDs, which preserve ICA flow during CAS. However, ICA flow arrest may occur with filter use. This report describes the angiographic, clinical, and histopathologic features of the filter occlusion.
MATERIALS AND METHODS: Sixty-one consecutive patients with cervical carotid stenosis treated by CAS by using a single type of filter device were evaluated. All patients were on dual antiplatelet treatment and fully heparinized. Prestent dilation was performed in all patients. Poststent dilation was performed in 15 patients. Control angiograms were obtained and evaluated after each step of the CAS procedure. All filters were inspected for debris, and if present, histology was obtained.
RESULTS: CAS was successfully performed in all cases with <20% residual stenosis. Filter occlusion occurred in 6 patients (9.8%). It developed immediately after stent deployment in 4, and after a second prestent dilation in 2. Five of the 6 had severe carotid stenosis. In all patients, filter withdrawal led to immediate and complete restoration of ICA flow. In 1 patient, acute embolic M1 occlusion occurred immediately after filter withdrawal but was successfully treated with thrombolysis. None of filter-occlusion group had permanent neurologic deficits. Gross and microscopic examinations demonstrated that the pores of the filters were occluded mainly by fibrin. Postoperative diffusion MR imaging revealed no difference between filter-occlusion and non-filter-occlusion groups.
CONCLUSIONS: ICA flow arrest due to filter occlusion during CAS is relatively common and occurs more frequently in severe stenosis. It resolves rapidly after filter removal and does not appear to worsen outcome.

Entities:  

Mesh:

Year:  2011        PMID: 22173773      PMCID: PMC7966437          DOI: 10.3174/ajnr.A2818

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  19 in total

Review 1.  Vulnerable plaque: the challenge to identify and treat it.

Authors:  Christodoulos Stefanadis; Manolis Vavuranakis; Pavlos Toutouzas
Journal:  J Interv Cardiol       Date:  2003-06       Impact factor: 2.279

Review 2.  Bidirectional relation between inflammation and coagulation.

Authors:  Marcel Levi; Tom van der Poll; Harry R Büller
Journal:  Circulation       Date:  2004-06-08       Impact factor: 29.690

3.  Cerebral protection with filter devices during carotid artery stenting.

Authors:  B Reimers; N Corvaja; S Moshiri; S Saccà; R Albiero; C Di Mario; P Pascotto; A Colombo
Journal:  Circulation       Date:  2001-07-03       Impact factor: 29.690

4.  Polyurethane: material for the next generation of heart valve prostheses?

Authors:  D J Wheatley; L Raco; G M Bernacca; I Sim; P R Belcher; J S Boyd
Journal:  Eur J Cardiothorac Surg       Date:  2000-04       Impact factor: 4.191

Review 5.  Histopathology of carotid atherosclerotic disease.

Authors:  Renu Virmani; Elena R Ladich; Allen P Burke; Frank D Kolodgie
Journal:  Neurosurgery       Date:  2006-11       Impact factor: 4.654

6.  Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

Authors:  G Maleux; P Demaerel; E Verbeken; K Daenens; S Heye; F Van Sonhoven; A Nevelsteen; G Wilms
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

7.  Protection filter-related events in extracranial carotid artery stenting: a single-center experience.

Authors:  Bae Ju Kwon; Moon Hee Han; Hyun-Seung Kang; Cheolkyu Jung
Journal:  J Endovasc Ther       Date:  2006-12       Impact factor: 3.487

8.  Extracranial thrombotically active carotid plaque as a risk factor for ischemic stroke.

Authors:  Luigi Giusto Spagnoli; Alessandro Mauriello; Giuseppe Sangiorgi; Stefano Fratoni; Elena Bonanno; Robert S Schwartz; David G Piepgras; Raimondo Pistolese; Arnaldo Ippoliti; David R Holmes
Journal:  JAMA       Date:  2004-10-20       Impact factor: 56.272

9.  Carotid angioplasty and stenting: will periprocedural transcranial Doppler monitoring be important?

Authors:  H Benichou; P Bergeron
Journal:  J Endovasc Surg       Date:  1996-05

10.  Transcranial Doppler monitoring in angioplasty and stenting of the carotid bifurcation.

Authors: 
Journal:  J Endovasc Ther       Date:  2003-08       Impact factor: 3.487

View more
  2 in total

1.  Recanalization of acute carotid stent occlusion using Penumbra 4Max aspiration catheter: technical report and review of rescue strategies for acute carotid stent occlusion.

Authors:  Stephan Munich; Roham Moftakhar; Demetrius Lopes
Journal:  BMJ Case Rep       Date:  2013-10-14

2.  Protected carotid artery stenting in patients with severe stenosis.

Authors:  Seo-Young Jeon; Jong-Myong Lee
Journal:  Medicine (Baltimore)       Date:  2022-08-19       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.