Literature DB >> 12696795

A quality assurance phantom for IMRT dose verification.

C M Ma1, S B Jiang, T Pawlicki, Y Chen, J S Li, J Deng, A L Boyer.   

Abstract

This paper investigates a quality assurance (QA) phantom specially designed to verify the accuracy of dose distributions and monitor units (MU) calculated by clinical treatment planning optimization systems and by the Monte Carlo method for intensity-modulated radiotherapy (IMRT). The QA phantom is a PMMA cylinder of 30 cm diameter and 40 cm length with various bone and lung inserts. A procedure (and formalism) has been developed to measure the absolute dose to water in the PMMA phantom. Another cylindrical phantom of the same dimensions, but made of water, was used to confirm the results obtained with the PMMA phantom. The PMMA phantom was irradiated by 4, 6 and 15 MV photon beams and the dose was measured using an ionization chamber and compared to the results calculated by a commercial inverse planning system (CORVUS, NOMOS, Sewickley, PA) and by the Monte Carlo method. The results show that the dose distributions calculated by both CORVUS and Monte Carlo agreed to within 2% of dose maximum with measured results in the uniform PMMA phantom for both open and intensity-modulated fields. Similar agreement was obtained between Monte Carlo calculations and measured results with the bone and lung heterogeneity inside the PMMA phantom while the CORVUS results were 4% different. The QA phantom has been integrated as a routine QA procedure for the patient's IMRT dose verification at Stanford since 1999.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12696795     DOI: 10.1088/0031-9155/48/5/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  An analysis of an implantable dosimeter system for external beam therapy.

Authors:  Robert D Black; Charles W Scarantino; Gregory G Mann; Mitchell S Anscher; Robert D Ornitz; Benjamin E Nelms
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-09-01       Impact factor: 7.038

3.  Optimized point dose measurement: An effective tool for QA in intensity-modulated radiotherapy.

Authors:  Alok Kumar; Gautam Mukherjee; Girigesh Yadav; Vinod Pandey; Kalyan Bhattacharya
Journal:  J Med Phys       Date:  2007-10

4.  Need of patient-specific quality assurance and pre-treatment verification program for special plans in radiotherapy.

Authors:  Ramamoorthy Ravichandran; Saju Bhasi; J P Binukumar; C A Davis
Journal:  J Med Phys       Date:  2011-07

5.  Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions.

Authors:  Teh Lin; Lu Wang; C-M Charlie Ma
Journal:  J Med Phys       Date:  2022-03-31

6.  Verification of inverse planning and treatment delivery for segmental IMRT.

Authors:  James L Bedford; Peter J Childs; Alan P Warrington
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

7.  Primo software as a tool for Monte Carlo simulations of intensity modulated radiotherapy: a feasibility study.

Authors:  Alessandro Esposito; Sofia Silva; Jorge Oliveira; Joana Lencart; João Santos
Journal:  Radiat Oncol       Date:  2018-05-15       Impact factor: 3.481

8.  Effect of isocenter deviation on volume modulated arc therapy plan results and gamma passing rate in the treatment of cervical cancer.

Authors:  Yuan Yuan; Xiao-Bin Chang; Li-Juan Hu; Guo-Qing Wang; Yan-Jun Xue
Journal:  Transl Cancer Res       Date:  2021-10       Impact factor: 1.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.