Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible.

Antonio Rocci1, Massimiliano Martignoni, Patricia Miranda Burgos, Jan Gottlow, Lars Sennerby.   

Abstract

BACKGROUND: An increased number of publications report that one-stage surgery and immediate/early loading of dental implants may be a feasible approach for prosthetic reconstruction of the edentate patient. However, little is known about the histologic response to implants subjected to immediate/early loading in patients.
PURPOSE: The aim of the present study was to histologically evaluate oxidized titanium implants subjected to loading immediately following surgery or after 2 months of healing and removed after 5 to 9 months loading.
MATERIALS AND METHODS: Five patients participated in the study; each had consulted for implant treatment in the posterior mandible and subsequently volunteered to have extra implants inserted for the purpose of histologic research. Nine oxidized titanium implants (Brånemark System TiUnite , Nobel Biocare AB, Gothenburg, Sweden) were retrieved after 5 to 9 months in function. Two implants had been loaded the same day, whereas seven implants were loaded after 2 months of healing. Resonance frequency analysis was performed at retrieval on seven implants. Ground sections were prepared for histology and analyzed using light microscopic morphometry.
RESULTS: Seven and 8.5 mm implants were placed, predominantly in quality 3 and 4 bone. Four implants were straight (Mk III), and five were tapered (Mk IV). All implants were clinically stable at retrieval and showed ISQ values of 65 to 79 with a mean of 71.4 +/- 4.4. Eight of the implants were able to be used for histology. A gross histologic examination showed an undisturbed healing of soft and bone tissues with no apparent differences between response to immediately and early loaded implants. Lamellar bone surrounded the implants, and remodeling was evident and more marked near the implant surface. A condensation of bone toward the implant surface was seen; this resulted in a lamina dura-like structure in trabecular bone. Thin rims of newly formed bone were often seen following the contour of the implant surface. The morphometric measurements showed a mean bone-to-implant contact value of 84.2 +/- 10.5% and a mean bone area value of 79.1 +/- 6.8%. The two immediately loaded implants showed bone-to-implant contact and bone area values of 92.9 +/- 0.1% and 84.9 +/- 0.9%, respectively. The corresponding values for the six early loaded implants were 81.4 +/- 10.6% and 77.1 +/- 6.8%, respectively.
CONCLUSIONS: The present study demonstrated that oxidized implants subjected to immediate or early loading do integrate with soft and bone tissues in the posterior mandible.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12691655     DOI: 10.1111/j.1708-8208.2003.tb00020.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  15 in total

1.  Comparative study of immediate functional loading and immediate non-functional loading of monocortical implants.

Authors:  J P Singh; A K Gupta; R K Dhiman; S K Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2014-03-12

2.  The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study.

Authors:  A Rocci; R Calcaterra; M DI Girolamo; M Rocci; C Rocci; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-07-23

3.  Histologic analysis of resorbable blasting media surface implants retrieved from humans: a report of two cases.

Authors:  Kyung-In Jeong; Young-Kyun Kim; Sang-Woon Moon; Su-Gwan Kim; Sung-Chul Lim; Pil-Young Yun
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-02-15

4.  Different performance of platform switching in equicrestal position implant: an histological study.

Authors:  A Rocci; R Calcaterra; M Rocci; C Rocci; M DI Girolamo; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

5.  Immediate loading: a new implant technique with immediate loading and aesthetics: Nobel Active™.

Authors:  D Moretto; M Gargari; E Nordsjö; F Gloria; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2009-02-01

6.  Comparing the TiOblast and Osseospeed surfaces. Histomorphometric and histological analysis in humans.

Authors:  M Rocci; A Rocci; M Martignoni; T Albrektsson; A Barlattani; M Gargari
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

7.  Osseointegration of bioactive microarc oxidized amorphous phase/TiO2 nanocrystals composited coatings on titanium after implantation into rabbit tibia.

Authors:  Rui Zhou; Daqing Wei; Haoyue Yang; Su Cheng; Wei Feng; Baoqiang Li; Yaming Wang; Dechang Jia; Yu Zhou
Journal:  J Mater Sci Mater Med       Date:  2014-01-31       Impact factor: 3.896

8.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

9.  The effect of various thread designs on the initial stability of taper implants.

Authors:  Ju-Hee Park; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

10.  Development of implant loading device for animal study about various loading protocol: a pilot study.

Authors:  Joon-Ho Yoon; Young-Bum Park; Yuna Cho; Chang-Sung Kim; Seong-Ho Choi; Hong-Seok Moon; Keun-Woo Lee; June-Sung Shim
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.