Literature DB >> 28042426

Different performance of platform switching in equicrestal position implant: an histological study.

A Rocci1, R Calcaterra2, M Rocci1, C Rocci1, M DI Girolamo3, L Baggi4.   

Abstract

OBJECTIVE: In this study we tested two different type of implant systems that were selected on the basis of differences in macrogeometry of platform switching in order to evaluate the behavior in term of BIC on the platform. MATERIAL AND
METHOD: The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant (3,6 mm in diameter and 6,5 mm in length GTBPlan1Health Amaro (UD) Italy) one type B implant (4 mm in diameter and 8 mm in length OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [3,6 mm in diameter and 6,5 mm in length GTB- Plan1Health Amaro, (UD), Italy] one type B implant (4 mm in diameter and 8 mm in length OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). All the implants were placed, by the same operator, in equicrestal position using "one stage" technique with a healing abutment at an adequate gingival height. After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. BIC upon platform was calculated considering as implant surface the platform length.
RESULTS: Our results showed that the mean percentage of BIC value related to platform surface placed in equicrestal position was higher in patients with type A implant than patients receiving type B implant independently from mandibular or maxillary positions. Moreover the mean percentage of BIC related to platform surface was significantly (p<0.05) higher in Group II/A than Group I/A.
CONCLUSIONS: Our data highlights that the particular features of the Bioplatform of Type A implant systems guarantee a higher value of BIC even if the implants were placed equicrestally.

Entities:  

Keywords:  histomorphometry; macrogeometry; microgeometry

Year:  2016        PMID: 28042426      PMCID: PMC5159930          DOI: 10.11138/orl/2016.9.1.011

Source DB:  PubMed          Journal:  Oral Implantol (Rome)        ISSN: 1974-5648


  28 in total

Review 1.  A role for surface topography in creating and maintaining bone at titanium endosseous implants.

Authors:  L F Cooper
Journal:  J Prosthet Dent       Date:  2000-11       Impact factor: 3.426

2.  A new microtomographic technique for non-invasive evaluation of the bone structure around implants.

Authors:  L Sennerby; A Wennerberg; F Pasop
Journal:  Clin Oral Implants Res       Date:  2001-02       Impact factor: 5.977

3.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

4.  Mechanical characterization of an innovative dental implant system.

Authors:  Maria Vittoria Diamanti; Barbara Del Curto; Alberto Barlattani; Patrizio Bollero; Liliana Ottria; Mariapia Pedeferri
Journal:  J Appl Biomater Biomech       Date:  2009 Jan-Apr

5.  Effects of Repeated Screw Tightening on Implant Abutment Interfaces in Terms of Bacterial and Yeast Leakage in Vitro: One-Time Abutment Versus the Multiscrewing Technique.

Authors:  Roberta Calcaterra; Michele Di Girolamo; Concetta Mirisola; Luigi Baggi
Journal:  Int J Periodontics Restorative Dent       Date:  2016 Mar-Apr       Impact factor: 1.840

Review 6.  Direct bone anchorage of dental implants.

Authors:  T Albrektsson
Journal:  J Prosthet Dent       Date:  1983-08       Impact factor: 3.426

7.  Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year.

Authors:  M Gargari; V Prete; M Pujia; F M Ceruso
Journal:  Oral Implantol (Rome)       Date:  2013-03-19

8.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

9.  Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone.

Authors:  Carl-Johan Ivanoff; Göran Widmark; Carina Johansson; Ann Wennerberg
Journal:  Int J Oral Maxillofac Implants       Date:  2003 May-Jun       Impact factor: 2.804

10.  Comparative evaluation of osseointegrated dental implants based on platform-switching concept: influence of diameter, length, thread shape, and in-bone positioning depth on stress-based performance.

Authors:  Luigi Baggi; Michele Di Girolamo; Giuseppe Vairo; Gianpaolo Sannino
Journal:  Comput Math Methods Med       Date:  2013-06-19       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.