Literature DB >> 7491179

Comparative study of three automatic programs of left ventricular ejection fraction evaluation.

P Véra1, I Gardin, B Bok.   

Abstract

The aim of this study was to compare three automatic programs (P1, P2, P3) for evaluating radionuclide left ventricular ejection fraction (LVEF) and to emphasize the clinical consequences. Gated radionuclide ventriculography was performed in 73 subjects, 15 of whom were healthy and 58 of whom had experienced heart failure. All scintigraphic data were processed with the three programs. Good inter-observer, intra-observer and automatic-manual reproducibility were observed using each of the three programs. On the other hand, in the normal subjects, the three mean normal LVEF values were significantly different from each other (P1 = 77 +/- 5%, P2 = 63 +/- 7%, P3 = 68 +/- 8%; P < 0.0001) In the pathological patients, the values obtained with P2 were significantly different from those obtained using P1 and P3 (P1= 32 +/- 15%, P2 = 26 +/- 13%; P < 0.0001), Moreover, the linear regression studies between the three automatic programs were always significantly different from the identity line equation (y = x). This study shows that LVEF criteria for normality depend on the program used, and inter-program measurement of LVEF is poorly reproducible. Caution is recommended when comparing data obtained from different centres (or different computers), either in the follow-up of a given patient or in gathering results from patient groups.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7491179     DOI: 10.1097/00006231-199508000-00008

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  5 in total

1.  Comparison of two three-dimensional gated SPECT methods with thallium in patients with large myocardial infarction.

Authors:  P Véra; R Koning; A Cribier; A Manrique
Journal:  J Nucl Cardiol       Date:  2000 Jul-Aug       Impact factor: 5.952

2.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

3.  Automatic quantification of right ventricular function with gated blood pool SPECT.

Authors:  Doumit Daou; Serge D Van Kriekinge; Carlos Coaguila; Rachida Lebtahi; Thierry Fourme; Olivier Sitbon; Florence Parent; Michel Slama; Dominique Le Guludec; Gerald Simonneau
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

4.  Comparison of interstudy reproducibility of equilibrium electrocardiography-gated SPECT radionuclide angiography versus planar radionuclide angiography for the quantification of global left ventricular function.

Authors:  Doumit Daou; Carlos Coaguila; Abdel Benada
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

5.  Evaluation of upconverting nanoparticles towards heart theranostics.

Authors:  Marc Kermorgant; Jennifer Ben Salem; Julien Santelli; Denis Calise; Anne-Cécile Oster; Olivier Lairez; Christophe Coudret; Marc Verelst; Céline Gales; Jean-Michel Sénard; Francis Beaudry; Anne Pavy-Le Traon; Clément Roux; Robert Mauricot; Dina N Arvanitis
Journal:  PLoS One       Date:  2019-12-09       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.