Literature DB >> 12662949

Cochlear implant failure: imaging evaluation of the electrode course.

R Jain1, S K Mukherji.   

Abstract

Cochlear implant (CI) is an electronic device used to rehabilitate patients with sensorineural hearing loss. The intent of this review is to demonstrate the normal position of the electrode on computed tomography (CT) and contrast this with various examples of the electrode malpositioning. Post-implantation CT is performed to localize the cause of implant failure in patients in which radiographs suggest an anomalous course of the electrode. A common cause of device failure is extrusion or malpositioning of the electrode. It is important for the radiologists to recognize this important aspect of device failure. Post-implant CT can help identify patients with malpositioned electrode in whom another attempt can be made by correctly re-implanting the electrode.

Entities:  

Mesh:

Year:  2003        PMID: 12662949     DOI: 10.1016/s0009-9260(02)00523-8

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  8 in total

1.  Relationship of cochlea with surrounding neurovascular structures and their implication in cochlear implantation.

Authors:  Daisy Sahni; Anjali Singla; Ashok Gupta; Tulika Gupta; Anjali Aggarwal
Journal:  Surg Radiol Anat       Date:  2015-02-08       Impact factor: 1.246

Review 2.  The Forgotten Second Window: A Pictorial Review of Round Window Pathologies.

Authors:  J C Benson; F Diehn; T Passe; J Guerin; V M Silvera; M L Carlson; J Lane
Journal:  AJNR Am J Neuroradiol       Date:  2019-12-12       Impact factor: 3.825

3.  Cochlear implant electrode misplacement: incidence, evaluation, and management.

Authors:  Yu-Lan Mary Ying; Jerry W Lin; John S Oghalai; Robert A Williamson
Journal:  Laryngoscope       Date:  2013-01-08       Impact factor: 3.325

4.  Revision surgeries in cochlear implant patients: a review of 45 cases.

Authors:  Lela Migirov; Riki Taitelbaum-Swead; Minka Hildesheimer; Jona Kronenberg
Journal:  Eur Arch Otorhinolaryngol       Date:  2006-09-29       Impact factor: 2.503

5.  A Retrospective Study of Cochlear Re-Implantations - Experience from a Large Centre in India.

Authors:  Abha Kumari; Sunil Goyal; Senthil Vadivu Arumugam; Viswanathan Vasumathi; Neha Chauhan; Mohan Kameswaran
Journal:  Turk Arch Otorhinolaryngol       Date:  2019-03-01

6.  Evaluation of 4 multisection CT systems in postoperative imaging of a cochlear implant: a human cadaver and phantom study.

Authors:  B M Verbist; R M S Joemai; W M Teeuwisse; W J H Veldkamp; J Geleijns; J H M Frijns
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-15       Impact factor: 3.825

7.  Histopathological Effects of Parylene C (poly-chloro-p-xylylene) in the Inner Ear.

Authors:  Raşit Cevizci; Mehmet Düzlü; Pınar Göçün Uyar; Recep Karamert; Selin Üstün Bezgin; Hakan Tutar; Nebil Göksu; Yıldırım Ahmet Bayazıt
Journal:  Turk Arch Otorhinolaryngol       Date:  2016-06-01

8.  Intra-operative radiological diagnosis of a tip roll-over electrode array displacement using fluoroscopy, when electrophysiological testing is normal: the importance of both techniques in cochlear implant surgery.

Authors:  Octavio Garaycochea; Raquel Manrique-Huarte; Manuel Manrique
Journal:  Braz J Otorhinolaryngol       Date:  2017-06-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.