Literature DB >> 12659915

Nonlinear coded excitation method for ultrasound contrast imaging.

Jerome M G Borsboom1, Chien Ting Chin, Nico de Jong.   

Abstract

Coded excitation with compression on receive is used in medical ultrasound (US) imaging to increase signal-to-noise ratio (SNR) and penetration depth. We performed a computer simulation study to investigate if chirped pulse excitation can be applied in US contrast agent imaging to increase SNR and contrast-to-tissue ratio (CTR) and, thus, reduce contrast agent destruction and tissue harmonics. A new nonlinear compression technique is proposed that selectively compresses the second harmonic component of the response. We compared a chirp of 9.4-micros duration, 2-MHz centre frequency, 45% relative bandwidth to a Gaussian pulse with equal centre frequency and bandwidth. For peak pressures between 50 and 300 kPa, we found for resonant bubbles an increase in response between 10 and 13 dB. Moreover, the axial resolution after compression was comparable to axial resolution of conventional imaging. This effect was relatively insensitive to peak excitation pressure and was largest for bubbles having resonance frequency around the centre frequency of the excitation.

Mesh:

Substances:

Year:  2003        PMID: 12659915     DOI: 10.1016/s0301-5629(02)00712-3

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  10 in total

1.  Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Coded pulse excitation for ultrasonic strain imaging.

Authors:  Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

3.  Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

Authors:  Yang Sun; Shukui Zhao; Paul A Dayton; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

4.  High-frequency dynamics of ultrasound contrast agents.

Authors:  Yang Sun; Dustin E Kruse; Paul A Dayton; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-11       Impact factor: 2.725

Review 5.  Microbubble ultrasound contrast agents: an update.

Authors:  Emilio Quaia
Journal:  Eur Radiol       Date:  2007-03-10       Impact factor: 5.315

6.  Optimization of Contrast-to-Tissue Ratio Through Pulse Windowing in Dual-Frequency "Acoustic Angiography" Imaging.

Authors:  Brooks D Lindsey; Sarah E Shelton; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-03-25       Impact factor: 2.998

7.  The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: implications for high-frequency nonlinear imaging.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

8.  Application of a second-generation US contrast agent in infants and children--a European questionnaire-based survey.

Authors:  Michael Riccabona
Journal:  Pediatr Radiol       Date:  2012-10-03

Review 9.  Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering.

Authors:  Shengping Qin; Charles F Caskey; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

10.  Improved shear wave motion detection using coded excitation for transient elastography.

Authors:  Xiao-Nian He; Xian-Fen Diao; Hao-Ming Lin; Xin-Yu Zhang; Yuan-Yuan Shen; Si-Ping Chen; Zheng-Di Qin; Xin Chen
Journal:  Sci Rep       Date:  2017-03-15       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.