Literature DB >> 12658083

Diurnal variation of corneal sensitivity and thickness.

Rènée du Toit1, José A Vega, Desmond Fonn, Trefford Simpson.   

Abstract

PURPOSE: To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours.
METHODS: A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00.
RESULTS: Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 +/- 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 +/- 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8; p < 0.05). DISCUSSION: Corneal sensitivity correlated with corneal thickness: both were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.

Entities:  

Mesh:

Year:  2003        PMID: 12658083     DOI: 10.1097/00003226-200304000-00004

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  26 in total

1.  Corneal and conjunctival sensitivity to air stimuli.

Authors:  F Stapleton; M E Tan; E B Papas; K Ehrmann; B Golebiowski; J Vega; B A Holden
Journal:  Br J Ophthalmol       Date:  2004-12       Impact factor: 4.638

2.  Conjunctival and corneal sensitivity in patients under topical antiglaucoma treatment.

Authors:  Lorena Romero-Díaz de León; Jorge-Emmanuel Morales-León; Jasbeth Ledesma-Gil; Alejandro Navas
Journal:  Int Ophthalmol       Date:  2015-08-14       Impact factor: 2.031

3.  Diurnal variations of central corneal thickness and intraocular pressure in dogs from 8:00 am to 8:00 pm.

Authors:  Eva Martín-Suárez; Carolina Molleda; Rodrigo Tardón; Alba Galán; José Gallardo; José Molleda
Journal:  Can Vet J       Date:  2014-04       Impact factor: 1.008

4.  Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT.

Authors:  David Kuerten; Niklas Plange; Eva Charlotte Koch; Antonis Koutsonas; Peter Walter; Matthias Fuest
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-21       Impact factor: 3.117

5.  Association between tear film break up time and blink interval in visual display terminal users.

Authors:  Miki Uchino; Motoko Kawashima; Yuichi Uchino; Kazuo Tsubota; Norihiko Yokoi
Journal:  Int J Ophthalmol       Date:  2018-10-18       Impact factor: 1.779

6.  South African Eye Study (SAES): ethnic differences in central corneal thickness and intraocular pressure.

Authors:  S O Baboolal; D P Smit
Journal:  Eye (Lond)       Date:  2018-01-12       Impact factor: 3.775

7.  Hypersensitivity to Cold Stimuli in Symptomatic Contact Lens Wearers.

Authors:  Ping Situ; Trefford Simpson; Carolyn Begley
Journal:  Optom Vis Sci       Date:  2016-08       Impact factor: 1.973

8.  Central corneal thickness and anterior chamber depth measurement by Sirius(®) Scheimpflug tomography and ultrasound.

Authors:  J Jorge; Jl Rosado; Ja Díaz-Rey; Jm González-Méijome
Journal:  Clin Ophthalmol       Date:  2013-02-26

Review 9.  Extraocular, periocular, and intraocular routes for sustained drug delivery for glaucoma.

Authors:  Uday B Kompella; Rachel R Hartman; Madhoosudan A Patil
Journal:  Prog Retin Eye Res       Date:  2020-09-04       Impact factor: 21.198

10.  Short-term stability in refractive status despite large fluctuations in glucose levels in diabetes mellitus type 1 and 2.

Authors:  Byki Huntjens; W Neil Charman; Helena Workman; Sarah L Hosking; Clare O'Donnell
Journal:  PLoS One       Date:  2012-12-28       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.