Effects of preheating of hip prostheses on the stem-cement interface.

Kazuho Iesaka1, William L Jaffe, Frederick J Kummer.   

Abstract

BACKGROUND: Debonding of the cement from metal implants has been implicated in the loosening of cemented total hip prostheses. Strengthening of the stem-cement interface has been suggested as a way to prevent loosening of the component. Previously, it was reported that preheating the stem to 44 degrees C reduced the porosity of the cement at the stem-cement interface. The purpose of this study was to determine the effect of stem preheating on the characteristics of the stem-cement interface.
METHODS: The effects of stem preheating, at temperatures of 37 degrees C, 44 degrees C, and 50 degrees C, on the stem-cement interface were studied in a test model and a preparation that closely simulated the clinical situation. Static interface strength was determined initially and after the stems had been kept in isotonic saline solution at 37 degrees C for two weeks. Fatigue lifetimes were measured, and the nature and extent of porosity at the interface were quantified.
RESULTS: Stem preheating had significant effects on the stem-cement interface. Stems preheated to 37 degrees C had greater interface shear strength than stems at room temperature both initially (53% greater strength) and after simulated aging (155% greater strength). Fatigue lifetimes were also improved, and there was a >99% decrease in interface porosity. The setting time of the cement decreased 12%, and the maximum temperature at the cement-bone interface increased 6 degrees C. Similar effects were found after preheating to 44 degrees C and 50 degrees C.
CONCLUSIONS: Stem preheating had significant effects on the stem-cement interface, with significant improvements in the shear strength and cement porosity of the interface. Also, polymerization temperatures at the cement-bone interface increased. The possible biological effects of these increased interface temperatures at the cement-bone interface require further study.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12637425     DOI: 10.2106/00004623-200303000-00003

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  5 in total

1.  Fatigue debonding of the roughened stem-cement interface: effects of surface roughness and stem heating conditions.

Authors:  Leatha A Damron; Do-Gyoon Kim; Kenneth A Mann
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-07       Impact factor: 3.368

2.  Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.

Authors:  Kenneth A Mann; Leatha A Damron; Mark A Miller; Amos Race; Michael T Clarke; Richard J Cleary
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

3.  Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: an in vitro laboratory investigation.

Authors:  K J Messick; M A Miller; L A Damron; A Race; M T Clarke; K A Mann
Journal:  J Bone Joint Surg Br       Date:  2007-08

4.  Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Adriana Zoppi; Eduardo A Salvati
Journal:  Int Orthop       Date:  2006-03-31       Impact factor: 3.075

5.  Effect of antibiotic loading on the shear strength at the stem-cement interface (Shear strength of antibiotic loaded cement).

Authors:  Onder Kilicoglu; L Ozgur Koyuncu; V Emre Ozden; Ergun Bozdag; Emin Sunbuloglu; Onder Yazicioglu
Journal:  Int Orthop       Date:  2007-03-14       Impact factor: 3.075

  5 in total