Kazuho Iesaka1, William L Jaffe, Frederick J Kummer. 1. Department of Orthopaedic Surgery, Musculoskeletal Research Center, New York University-Hospital for Joint Diseases, New York, NY 10003, USA. kazuho@biomech.org
Abstract
BACKGROUND: Debonding of the cement from metal implants has been implicated in the loosening of cemented total hip prostheses. Strengthening of the stem-cement interface has been suggested as a way to prevent loosening of the component. Previously, it was reported that preheating the stem to 44 degrees C reduced the porosity of the cement at the stem-cement interface. The purpose of this study was to determine the effect of stem preheating on the characteristics of the stem-cement interface. METHODS: The effects of stem preheating, at temperatures of 37 degrees C, 44 degrees C, and 50 degrees C, on the stem-cement interface were studied in a test model and a preparation that closely simulated the clinical situation. Static interface strength was determined initially and after the stems had been kept in isotonic saline solution at 37 degrees C for two weeks. Fatigue lifetimes were measured, and the nature and extent of porosity at the interface were quantified. RESULTS: Stem preheating had significant effects on the stem-cement interface. Stems preheated to 37 degrees C had greater interface shear strength than stems at room temperature both initially (53% greater strength) and after simulated aging (155% greater strength). Fatigue lifetimes were also improved, and there was a >99% decrease in interface porosity. The setting time of the cement decreased 12%, and the maximum temperature at the cement-bone interface increased 6 degrees C. Similar effects were found after preheating to 44 degrees C and 50 degrees C. CONCLUSIONS: Stem preheating had significant effects on the stem-cement interface, with significant improvements in the shear strength and cement porosity of the interface. Also, polymerization temperatures at the cement-bone interface increased. The possible biological effects of these increased interface temperatures at the cement-bone interface require further study.
BACKGROUND: Debonding of the cement from metal implants has been implicated in the loosening of cemented total hip prostheses. Strengthening of the stem-cement interface has been suggested as a way to prevent loosening of the component. Previously, it was reported that preheating the stem to 44 degrees C reduced the porosity of the cement at the stem-cement interface. The purpose of this study was to determine the effect of stem preheating on the characteristics of the stem-cement interface. METHODS: The effects of stem preheating, at temperatures of 37 degrees C, 44 degrees C, and 50 degrees C, on the stem-cement interface were studied in a test model and a preparation that closely simulated the clinical situation. Static interface strength was determined initially and after the stems had been kept in isotonic saline solution at 37 degrees C for two weeks. Fatigue lifetimes were measured, and the nature and extent of porosity at the interface were quantified. RESULTS: Stem preheating had significant effects on the stem-cement interface. Stems preheated to 37 degrees C had greater interface shear strength than stems at room temperature both initially (53% greater strength) and after simulated aging (155% greater strength). Fatigue lifetimes were also improved, and there was a >99% decrease in interface porosity. The setting time of the cement decreased 12%, and the maximum temperature at the cement-bone interface increased 6 degrees C. Similar effects were found after preheating to 44 degrees C and 50 degrees C. CONCLUSIONS: Stem preheating had significant effects on the stem-cement interface, with significant improvements in the shear strength and cement porosity of the interface. Also, polymerization temperatures at the cement-bone interface increased. The possible biological effects of these increased interface temperatures at the cement-bone interface require further study.
Authors: Kenneth A Mann; Leatha A Damron; Mark A Miller; Amos Race; Michael T Clarke; Richard J Cleary Journal: J Orthop Res Date: 2007-03 Impact factor: 3.494
Authors: Onder Kilicoglu; L Ozgur Koyuncu; V Emre Ozden; Ergun Bozdag; Emin Sunbuloglu; Onder Yazicioglu Journal: Int Orthop Date: 2007-03-14 Impact factor: 3.075