BACKGROUND: The value of the impedance cardiography (IC) method for measuring cardiac output (CO) with the subject in the left lateral position has not yet been established. We compared the CO after a 30 degrees head-up tilt with the subjects in the supine and left lateral position.
METHODS: Thirty healthy young volunteers were placed in the supine horizontal position. CO, stroke volume (SV) and heart rate (HR) were measured for five minutes using impedance cardiography (NCOMM3, BoMed Medical Manufacturing, Location). Then a 30 degrees head-up tilt was done and the measurements were continued for an additional five minutes. After that the subjects were placed in the left lateral horizontal position and the measuring procedure was repeated.
RESULTS: After the tilt, SV and cardiac index (CI) decreased and HR increased statistically significantly in the supine and in the left lateral position. SV and CI also decreased statistically significantly but HR did not change after the shift from the supine to the left lateral position. Although CI was smaller in the left lateral position, the time course of CI change after the tilt was identical in the supine and in the left lateral position.
CONCLUSION: When using the IC method of SV measurement, the absolute value of the CI changes when moving from the supine to lateral positions. It is not clear whether this change is physiologic or an artifact of the measurement technique. However, changes in CI in response to a 30 degree head up tilt are the same in either position. We conclude that changes in CI can be measured with the IC method in the lateral position.

Entities:  

Mesh:

Year:  1999        PMID: 12578050     DOI: 10.1023/a:1009968513512

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Cardiac responses to the Valsalva manoeuvre in different body positions.

Authors:  H Olschewski; K Brück
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

2.  Electrical bioimpedance for noninvasive cardiac measurement.

Authors:  L A Critchley; R Calcroft
Journal:  Crit Care Med       Date:  1998-08       Impact factor: 7.598

3.  Optimalisation of the spot electrode array in impedance cardiography.

Authors:  H H Woltjer; B W Arntzen; H J Bogaard; P M de Vries
Journal:  Med Biol Eng Comput       Date:  1996-01       Impact factor: 2.602

4.  Noninvasive versus invasive assessment of cardiac output after cardiac surgery: clinical validation.

Authors:  D R Spahn; E R Schmid; M Tornic; R Jenni; L von Segesser; M Turina; A Baetscher
Journal:  J Cardiothorac Anesth       Date:  1990-02

Review 5.  Assessment of the haemodynamic response to exercise by means of electrical impedance cardiography: method, validation and clinical applications.

Authors:  H J Bogaard; H H Woltjer; P E Postmus; P M de Vries
Journal:  Physiol Meas       Date:  1997-05       Impact factor: 2.833

6.  Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution.

Authors:  H H Woltjer; H J Bogaard; G J Scheffer; H I van der Spoel; M A Huybregts; P M de Vries
Journal:  Br J Anaesth       Date:  1996-12       Impact factor: 9.166

7.  A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale.

Authors:  D P Bernstein
Journal:  Crit Care Med       Date:  1986-10       Impact factor: 7.598

8.  A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques.

Authors:  S L Clark; J Southwick; J M Pivarnik; D B Cotton; G D Hankins; J P Phelan
Journal:  Obstet Gynecol       Date:  1994-05       Impact factor: 7.661

9.  Cardiac output measurement in critical care patients: Thoracic Electrical Bioimpedance versus thermodilution.

Authors:  T V Clancy; K Norman; R Reynolds; D Covington; J G Maxwell
Journal:  J Trauma       Date:  1991-08

10.  Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution.

Authors:  L Doering; E Lum; K Dracup; A Friedman
Journal:  Crit Care Med       Date:  1995-10       Impact factor: 7.598

View more
  1 in total

1.  Monitoring of vecuronium-induced neuromuscular blockade during one-lung ventilation.

Authors:  Yuhji Saitoh; Tsutomu Oshima; Yoshinori Nakata
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.