Abstract

OBJECTIVES: To evaluate the usefulness of transthoracic electrical bioimpedance in trending changes in cardiac output after cardiac surgery, and to identify predictors of differences between cardiac output measured by thermodilution and transthoracic electrical bioimpedance methods.
DESIGN: Prospective repeated-measures study.
SETTING: University-affiliated tertiary care center. PATIENTS: Thirty-four adult patients undergoing elective cardiac surgery with routine pulmonary artery catheter placement.
INTERVENTIONS: Simultaneous paired cardiac output measurements by transthoracic electrical bioimpedance and thermodilution were made at four time points: within 2 hrs of intensive care unit (ICU) admission; when the patient reached a normothermic temperature; after extubation; and 24 hrs after ICU admission.
MEASUREMENTS AND MAIN RESULTS: Mean measurements by each method over time did not differ, except at ICU admission, when compared by repeated-measures analysis of variance. For each time point, bias and precision between methods were calculated. Bias calculations ranged from 0.02 to 0.21 L/min/m2. Precision calculations ranged from 1.06 to 1.52 L/min/m2. Predictors of between-method differences identified by a multiple regression model of hemodynamic variables were: increased systemic vascular resistance index, decreased mean arterial pressure (MAP), and the presence of atrial or ventricular pacing.
CONCLUSIONS: While mean postoperative cardiac output measurements did not differ by method over time, agreement between transthoracic electrical bioimpedance and thermodilution methods was poor in the immediate postoperative period, with precision calculations indicative of clinically significant differences. Increased systemic vascular resistance index and decreased MAP were predictive of larger between-method differences.

Entities:  

Mesh:

Year:  1995        PMID: 7587231     DOI: 10.1097/00003246-199510000-00010

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

1.  The influence of left lateral position on cardiac output changes after head up tilt measured by impedance cardiography.

Authors:  M Kamenik
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

Review 2.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

Review 3.  Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Giorgio della Rocca; Maxime Cannesson; Christoph K Hofer
Journal:  Curr Heart Fail Rep       Date:  2010-09

4.  Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution.

Authors:  Stefan Suttner; Thilo Schöllhorn; Joachim Boldt; Jochen Mayer; Kerstin D Röhm; Katrin Lang; Swen N Piper
Journal:  Intensive Care Med       Date:  2006-10-13       Impact factor: 17.440

5.  Cardiovascular correlates of insulin resistance in normotensive and hypertensive African Americans.

Authors:  Srividya Kidambi; Jane M Kotchen; Shanthi Krishnaswami; Clarence E Grim; Theodore A Kotchen
Journal:  Metabolism       Date:  2010-09-16       Impact factor: 8.694

Review 6.  Measuring impedance in congestive heart failure: current options and clinical applications.

Authors:  W H Wilson Tang; Wilson Tong
Journal:  Am Heart J       Date:  2008-12-16       Impact factor: 4.749

7.  Biological variation of the cardiac index in patients with stable chronic heart failure: inert gas rebreathing compared with impedance cardiography.

Authors:  Tobias Täger; Hanna Fröhlich; Jennifer Franke; Karen Slottje; Andrea Horsch; Dietmar Zdunek; Georg Hess; Andreas Dösch; Hugo A Katus; Frank H Wians; Lutz Frankenstein
Journal:  ESC Heart Fail       Date:  2015-06-15

8.  A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves.

Authors:  Maurits K Konings; Henk G Goovaerts; Maarten R Roosendaal; Rienk Rienks; Ferry M Koevoets; Ronald L Bleys; Wolfgang F Buhre; Paul M Dorresteijn; Tim Hesselink; Arthur E Officier; Charles L Hollenkamp; Frank E Rademakers
Journal:  Biomed Eng Online       Date:  2012-08-17       Impact factor: 2.819

9.  Assessment of stroke volume index with three different bioimpedance algorithms: lack of agreement compared to thermodilution.

Authors:  Eric E C de Waal; Maurits K Konings; Cor J Kalkman; Wolfgang F Buhre
Journal:  Intensive Care Med       Date:  2008-01-08       Impact factor: 17.440

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.