Literature DB >> 25973340

Effect of reconstruction algorithms on the accuracy of (99m)Tc sestamibi SPECT/CT parathyroid imaging.

Kenneth J Nichols1, Gene G Tronco1, Christopher J Palestro1.   

Abstract

The superiority of SPECT/CT over SPECT for (99m)Tc-sestamibi parathyroid imaging often is assumed to be due to improved lesion localization provided by the anatomic component (computed tomography) of the examination. It also is possible that this superiority may be related to the algorithms used for SPECT data reconstruction. The objective of this investigation was to determine the effect of SPECT reconstruction algorithms on the accuracy of MIBI SPECT/CT parathyroid imaging. We retrospectively analyzed preoperative MIBI SPECT/CT parathyroid imaging studies performed on 106 patients. SPECT data were reconstructed by filtered back projection (FBP) and by iterative reconstruction with corrections for collimator resolution recovery and attenuation (IRC). Two experienced readers independently graded lesion detection certainty on a 5-point scale without knowledge of each other's readings, reconstruction methods, other test results or final diagnoses. All patients had surgical confirmation of the final diagnosis, including disease limited to the neck, and location and weight of excised lesion(s). There were 135 parathyroid lesions among the 106 patients. For FBP SPECT/CT and IRC SPECT/CT sensitivity was 76% and 90% (p = 0.003), specificity was 87% and 87% (p = 0.90), and accuracy was 83% and 88% (p = 0.04), respectively. Inter-rater agreement was significantly higher for IRC than for FBP (kappa = 0.76, "good agreement", versus kappa = 0.58, "moderate agreement", p < 0.0001). We conclude that the improved accuracy of MIBI SPECT/CT compared to MIBI SPECT for preoperative parathyroid lesion localization is due in part to the use of IRC for SPECT data reconstruction.

Entities:  

Keywords:  99mTc-sestamibi; MIBI; Parathyroid; SPECT/CT; filtered back projection; iterative reconstruction

Year:  2015        PMID: 25973340      PMCID: PMC4396014     

Source DB:  PubMed          Journal:  Am J Nucl Med Mol Imaging


  14 in total

1.  Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT.

Authors:  Doumit Daou; Isabelle Pointurier; Carlos Coaguila; Didier Vilain; Abdel Wahab Benada; Rachida Lebtahi; Thierry Fourme; Michel Slama; Dominique Le Guludec
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

Review 2.  Determination of the attenuation map in emission tomography.

Authors:  Habib Zaidi; Bruce Hasegawa
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

3.  Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging.

Authors:  Pierre Gantet; Pierre Payoux; Anna Celler; Cynthia Majorel; Daniel Gourion; Dominikus Noll; Jean-Paul Esquerré
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

4.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

5.  Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recovery.

Authors:  T S Pan; D S Luo; V Kohli; M A King
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

6.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

7.  Radioguided surgery of primary hyperparathyroidism using the low-dose 99mTc-sestamibi protocol: multiinstitutional experience from the Italian Study Group on Radioguided Surgery and Immunoscintigraphy (GISCRIS).

Authors:  Domenico Rubello; Maria Rosa Pelizzo; Giuseppe Boni; Riccardo Schiavo; Luca Vaggelli; Giuseppe Villa; Sergio Sandrucci; Andrea Piotto; Gianpiero Manca; Pierluigi Marini; Giuliano Mariani
Journal:  J Nucl Med       Date:  2005-02       Impact factor: 10.057

8.  Preoperative parathyroid scintigraphic lesion localization: accuracy of various types of readings.

Authors:  Kenneth J Nichols; Maria B Tomas; Gene G Tronco; Josephine N Rini; Biju D Kunjummen; Keith S Heller; Laura A Sznyter; Christopher J Palestro
Journal:  Radiology       Date:  2008-05-15       Impact factor: 11.105

9.  Phantom experiments to improve parathyroid lesion detection.

Authors:  Kenneth J Nichols; Gene G Tronco; Maria B Tomas; Biju D Kunjummen; Lisa Siripun; Josephine N Rini; Christopher J Palestro
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

10.  Virtual neck exploration: a new method for localizing abnormal parathyroid glands.

Authors:  Rupert Prommegger; Gerd Wimmer; Christoph Profanter; Tonja Sauper; Michael Sieb; Peter Kovacs; Reto Bale; Daniel Putzer; Michael Gabriel; Raimund Margreiter
Journal:  Ann Surg       Date:  2009-11       Impact factor: 12.969

View more
  3 in total

1.  Intraoperative localization of the parathyroid glands with indocyanine green and Firefly(R) technology during BABA robotic thyroidectomy.

Authors:  Hyeong Won Yu; Joon Woo Chung; Jin Wook Yi; Ra-Yeong Song; Joon-Hyop Lee; Hyungju Kwon; Su-Jin Kim; Young Jun Chai; June Young Choi; Kyu Eun Lee
Journal:  Surg Endosc       Date:  2016-11-18       Impact factor: 4.584

2.  99mTc-Sestamibi/123I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?

Authors:  Virpi Tunninen; Pekka Varjo; Tomi Kauppinen; Anu Holm; Hannu Eskola; Marko Seppänen
Journal:  Int J Mol Imaging       Date:  2017-10-18

3.  Preoperative injection of carbon nanoparticles is beneficial to the patients with thyroid papillary carcinoma: From a prospective study of 102 cases.

Authors:  Shouyi Yan; Wenxin Zhao; Bo Wang; Liyong Zhang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.