Literature DB >> 19629610

Prospects for advancing nuclear cardiology by means of new detector designs.

Kenneth J Nichols, Andrew Van Tosh, Christopher J Palestro.   

Abstract

Mesh:

Year:  2009        PMID: 19629610     DOI: 10.1007/s12350-009-9123-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


× No keyword cloud information.
  37 in total

1.  Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT.

Authors:  Doumit Daou; Isabelle Pointurier; Carlos Coaguila; Didier Vilain; Abdel Wahab Benada; Rachida Lebtahi; Thierry Fourme; Michel Slama; Dominique Le Guludec
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

2.  Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT.

Authors:  Jianbin Xiao; Tim C de Wit; Steven G Staelens; Freek J Beekman
Journal:  J Nucl Med       Date:  2006-10       Impact factor: 10.057

3.  Normal limits of gated blood pool SPECT count-based regional cardiac function parameters.

Authors:  Kenneth J Nichols; Andrew Van Tosh; Pieter De Bondt; Steven R Bergmann; Christopher J Palestro; Nathaniel Reichek
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-31       Impact factor: 2.357

4.  Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients.

Authors:  L L Demer; K L Gould; R A Goldstein; R L Kirkeeide; N A Mullani; R W Smalling; A Nishikawa; M E Merhige
Journal:  Circulation       Date:  1989-04       Impact factor: 29.690

5.  Significance of reduced uptake of iodinated fatty acid analogue for the evaluation of patients with acute chest pain.

Authors:  Y Kawai; E Tsukamoto; Y Nozaki; K Morita; M Sakurai; N Tamaki
Journal:  J Am Coll Cardiol       Date:  2001-12       Impact factor: 24.094

6.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

7.  Absolute quantitation of myocardial blood flow with (201)Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling.

Authors:  Hidehiro Iida; Stefan Eberl; Kyeong-Min Kim; Yoshikazu Tamura; Yukihiko Ono; Mayumi Nakazawa; Antti Sohlberg; Tsutomu Zeniya; Takuya Hayashi; Hiroshi Watabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-15       Impact factor: 9.236

8.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

9.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

10.  Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging.

Authors:  V Dilsizian; T P Rocco; N M Freedman; M B Leon; R O Bonow
Journal:  N Engl J Med       Date:  1990-07-19       Impact factor: 91.245

View more
  4 in total

1.  Dedicated cardiac cameras: a new option for nuclear myocardial perfusion imaging.

Authors:  Orazio Schillaci; Roberta Danieli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

Review 2.  Recent advances in cardiac SPECT instrumentation and system design.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

3.  CZT cameras: A technological jump for myocardial perfusion SPECT.

Authors:  Laetitia Imbert; Pierre-Yves Marie
Journal:  J Nucl Cardiol       Date:  2015-06-25       Impact factor: 5.952

Review 4.  Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

Authors:  Denis Agostini; Pierre-Yves Marie; Simona Ben-Haim; François Rouzet; Bernard Songy; Alessandro Giordano; Alessia Gimelli; Fabien Hyafil; Roberto Sciagrà; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-19       Impact factor: 9.236

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.