Wear of Morse taper and external hexagon implant joints after abutment removal.

Abraão M Prado1, Jorge Pereira2,3, Filipe S Silva4, Bruno Henriques4, Rubens M Nascimento5, Cesar A M Benfatti1, José López-López2, Júlio C M Souza6,7.   

Abstract

The aim of this in vitro study was to evaluate the removal torque values on abutments and the morphological wear aspects of two different dental implant joints after immersion in a medium containing biofilm from human saliva. Twenty implant-abutment assemblies were divided into four groups in this study: (A) Morse taper free of medium containing biofilm, and (B) after contact with a medium containing biofilm from human saliva; (C) External Hexagon free of medium containing biofilm, and (D) after contact with medium containing biofilm from human saliva. The abutments were firstly torqued to the implants according to the manufacturer´s recommendations, using a handheld torque meter. Groups B and D were immersed into 24 well-plates containing 2 ml BHI medium with microorganisms for 72 h at 37 °C under microaerophilic conditions. After detorque evaluation, the abutments were removed and the implants were analyzed by scanning electron microscopy (SEM) and profilometry. On the detorque evaluation, the torque values decreased for the external hexagon implants and increased for the Morse taper implants. However, the values were lower when both implant-abutment assemblies were in contact with a medium containing biofilm from human saliva. The wear areas of contacting surfaces of the implants were identified by SEM. The highest average roughness values were recorded on the surfaces free of biofilm. The medium containing biofilm from human saliva affected the maintenance of the torque values on Morse taper and external hexagon abutments. Additionally, the removal of abutment altered the inner implant surfaces resulting in an increase of wear of the titanium-based connection.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28321800     DOI: 10.1007/s10856-017-5879-6

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  22 in total

1.  Abutment selection in implant-supported fixed prosthodontics.

Authors:  G D Giglio
Journal:  Int J Periodontics Restorative Dent       Date:  1999-06       Impact factor: 1.840

2.  Preload loss and bacterial penetration on different implant-abutment connection systems.

Authors:  Antônio Pedro Ricomini Filho; Frederico Silva de Freitas Fernandes; Fabiana Gouveia Straioto; Wander José da Silva; Altair Antoninha Del Bel Cury
Journal:  Braz Dent J       Date:  2010

3.  Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling.

Authors:  Wirley Gonçalves Assunção; Valentim Adelino Ricardo Barão; Juliana Aparecida Delben; Érica Alves Gomes; Idelmo Rangel Garcia
Journal:  J Prosthodont Res       Date:  2010-06-08       Impact factor: 4.642

4.  Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.

Authors:  H C Quek; Keson B Tan; Jack I Nicholls
Journal:  Int J Oral Maxillofac Implants       Date:  2008 Mar-Apr       Impact factor: 2.804

5.  Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants.

Authors:  Mayara Barbosa Ferreira; Juliana Aparecida Delben; Valentim Adelino Ricardo Barão; Leonardo Perez Faverani; Paulo Henrique Dos Santos; Wirley Gonçalves Assunção
Journal:  J Craniofac Surg       Date:  2012-11       Impact factor: 1.046

6.  Biofilm Formation on Different Materials Used in Oral Rehabilitation.

Authors:  Júlio C M Souza; Raquel R C Mota; Mariane B Sordi; Bernardo B Passoni; Cesar A M Benfatti; Ricardo S Magini
Journal:  Braz Dent J       Date:  2016 Mar-Apr

7.  Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.

Authors:  S A Hoyer; C M Stanford; S Buranadham; T Fridrich; J Wagner; D Gratton
Journal:  J Prosthet Dent       Date:  2001-06       Impact factor: 3.426

8.  Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants.

Authors:  F J Gil; M Herrero-Climent; P Lázaro; J V Rios
Journal:  J Mater Sci Mater Med       Date:  2014-04-10       Impact factor: 3.896

9.  Load fatigue performance of conical implant-abutment connections.

Authors:  Y L Seetoh; Keson B Tan; E K Chua; H C Quek; Jack I Nicholls
Journal:  Int J Oral Maxillofac Implants       Date:  2011 Jul-Aug       Impact factor: 2.804

10.  Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments.

Authors:  R A Zavanelli; G E Pessanha Henriques; I Ferreira; J M De Almeida Rollo
Journal:  J Prosthet Dent       Date:  2000-09       Impact factor: 3.426

View more
  4 in total

1.  Complete mechanical characterization of an external hexagonal implant connection: in vitro study, 3D FEM, and probabilistic fatigue.

Authors:  María Prados-Privado; Sérgio A Gehrke; Rosa Rojo; Juan Carlos Prados-Frutos
Journal:  Med Biol Eng Comput       Date:  2018-06-11       Impact factor: 2.602

Review 2.  Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: an integrative review.

Authors:  Redouane Messous; Bruno Henriques; Hassan Bousbaa; Filipe S Silva; Wim Teughels; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-02-22       Impact factor: 3.573

3.  Sealing agent reduces formation of single and dual-species biofilms of Candida albicans and Enterococcus faecalis on screw joints at the abutment/implant interface.

Authors:  Cecília Alves de Sousa; Jadison Junio Conforte; Karina Sampaio Caiaffa; Cristiane Duque; Wirley Gonçalves Assunção
Journal:  PLoS One       Date:  2019-10-22       Impact factor: 3.240

4.  Effect of Implant Platform Connection and Abutment Material on Removal Torque and Implant Hexagon Plastic Deformation.

Authors:  Paulo Henrique de Souza Pereira; Marina Amaral; Kusai Baroudi; Rafael Pino Vitti; Mohammad Zakaria Nassani; Laís Regiane da Silva-Concílio
Journal:  Eur J Dent       Date:  2019-12-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.