Literature DB >> 12515877

Performance evaluation of a modular gamma camera using a detectability index.

John D Sain1, Harrison H Barrett.   

Abstract

UNLABELLED: The performance of a modular gamma camera for the task of detecting signals in random noisy backgrounds was evaluated experimentally. The results were compared with a theoretical computer simulation.
METHODS: The camera uses a 10 x 10 cm thallium-doped sodium iodide crystal, a 2 x 2 array of 53 x 53 mm photomultiplier tubes, and a parallel-hole collimator (1.5-mm bore width, 23.6-mm bore length). The camera was positioned to look down into a 10-cm-deep water bath that filled its field of view (FOV). The top surface of the water was 5 cm from the front face of the camera. The camera has 3-mm intrinsic spatial resolution (SR) in the center of its FOV and 9-mm system SR for objects 5 cm below the top surface of the water. Uniform and nonuniform random background data were collected by imaging the bath containing 740 MBq (20 mCi) (99m)Tc. Nonuniformities were created by placing water-filled objects in the bath. Each signal dataset was collected by imaging a water-filled plastic sphere, injected with (99m)Tc and set at a specific depth (Z) in the bath. Data were collected for many signal diameters (D) (4, 7, 10, 13, 16, 28 mm) at 1 depth (5 cm) and for 1 signal diameter (10 mm) at several depths (1, 3, 5, 7, 9 cm). Sets of signal-present/signal-absent image pairs (380 pairs, 10(5) events per image) for known contrasts (C) were generated for use in ideal-observer studies in which the detectability (d') was calculated. Contrast-detail (log C vs. log D) plots were created. The theoretical simulation, developed for uniform backgrounds, provided data for comparison.
RESULTS: The detectability increased linearly with C and decreased nonlinearly with decreasing D or increasing Z. The C required to achieve a specific d' increased sharply for D < SR. For C = 5, D = 10 mm, and d' = 1.2, the camera consistently detected signals for Z < 6 cm. Similar results were found for nonuniform backgrounds. The theoretical simulation verified the results for uniform backgrounds.
CONCLUSION: The methodology presented here provides a way of evaluating gamma cameras on the basis of signal-detection performance for specified lesions, with particular application to scintimammography.

Entities:  

Mesh:

Year:  2003        PMID: 12515877

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

1.  A modified uniform Cramer-Rao bound for multiple pinhole aperture design.

Authors:  L J Meng; N H Clinthorne
Journal:  IEEE Trans Med Imaging       Date:  2004-07       Impact factor: 10.048

2.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

3.  Rapid Computation of LROC Figures of Merit Using Numerical Observers (for SPECT/PET Reconstruction).

Authors:  Parmeshwar Khurd; Gene Gindi
Journal:  IEEE Trans Nucl Sci       Date:  2003       Impact factor: 1.679

4.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Assessment of a fluorescence-enhanced optical imaging system using the Hotelling observer.

Authors:  Amit K Sahu; Amit Joshi; Matthew A Kupinski; Eva M Sevick-Muraca
Journal:  Opt Express       Date:  2006-08-21       Impact factor: 3.894

6.  Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: impact of radiation dose and reconstruction algorithms.

Authors:  Lifeng Yu; Shuai Leng; Lingyun Chen; James M Kofler; Rickey E Carter; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071