Literature DB >> 12505786

One-second time resolution brain microdialysis in fully awake rats. Protocol for the collection, separation and sorting of nanoliter dialysate volumes.

Sergio Rossell1, Luis E Gonzalez, Luis Hernández.   

Abstract

Capillary zone electrophoresis is capable of analyzing nanoliter volumes, reducing the challenge posed by brain microdialysis time resolution improvement to the management of nanoliter dialysate volumes. This fact has not been overlooked and 12- and 6-s time resolution microdialysis have been reported in anesthetized rats. However, behavioral experiments require fully awake and freely moving animals. To achieve high temporal resolution brain microdialysis in awake unrestrained rats, we have developed an online device that mixes the outflowing dialysate with fluorescein isothiocyanate and buffer within a 26-nl reactor. The mixture was continuously accumulated in a 99-micrometer-bore capillary tube. After the experiment the tube was cut into 4-mm pieces and the content of each piece (30 nl, equivalent to 1 s dialysate) was transferred to a test tube. After allowing 18 h for derivatization, the samples were diluted with water and injected into a capillary electrophoresis laser-induced fluorescence detection instrument. This protocol was tested first in an in vitro assay and proved to be capable of detecting glutamate concentration changes in only 1 s. For the in vivo assays, a probe was inserted into the primary somatosensory cortex of eight rats divided in two groups. One group was stimulated by gently moving its whiskers for 10 s. The other group had no whisker manipulation. Moving the whiskers released glutamate in the experimental group. The first and only change was observed at the 12th s. This method allows 1-s time resolution brain microdialysis in freely moving rats and multiple amino acid analysis every second during sensory perception or motor actions in behavioral experiments.

Entities:  

Mesh:

Year:  2003        PMID: 12505786     DOI: 10.1016/s1570-0232(02)00826-7

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  12 in total

1.  In Vivo Monitoring of Dopamine by Microdialysis with 1 min Temporal Resolution Using Online Capillary Liquid Chromatography with Electrochemical Detection.

Authors:  Hui Gu; Erika L Varner; Stephen R Groskreutz; Adrian C Michael; Stephen G Weber
Journal:  Anal Chem       Date:  2015-05-26       Impact factor: 6.986

2.  Collection of nanoliter microdialysate fractions in plugs for off-line in vivo chemical monitoring with up to 2 s temporal resolution.

Authors:  Meng Wang; Thomas Slaney; Omar Mabrouk; Robert T Kennedy
Journal:  J Neurosci Methods       Date:  2010-05-04       Impact factor: 2.390

Review 3.  Electrochemical techniques for subsecond neurotransmitter detection in live rodents.

Authors:  Kevin N Hascup; Erin R Hascup
Journal:  Comp Med       Date:  2014-08       Impact factor: 0.982

4.  Quantitation of dopamine, serotonin and adenosine content in a tissue punch from a brain slice using capillary electrophoresis with fast-scan cyclic voltammetry detection.

Authors:  Huaifang Fang; Megan L Pajski; Ashley E Ross; B Jill Venton
Journal:  Anal Methods       Date:  2013       Impact factor: 2.896

5.  Collection, storage, and electrophoretic analysis of nanoliter microdialysis samples collected from awake animals in vivo.

Authors:  Meng Wang; Neil D Hershey; Omar S Mabrouk; Robert T Kennedy
Journal:  Anal Bioanal Chem       Date:  2011-04-05       Impact factor: 4.142

6.  A rotating operant chamber for use with microdialysis.

Authors:  Bart Degreef; Khanh T Ngo; Andrea Jaquins-Gerstl; Stephen G Weber
Journal:  J Neurosci Methods       Date:  2019-08-01       Impact factor: 2.390

7.  Second-by-second measures of L-glutamate in the prefrontal cortex and striatum of freely moving mice.

Authors:  K N Hascup; E R Hascup; F Pomerleau; P Huettl; G A Gerhardt
Journal:  J Pharmacol Exp Ther       Date:  2007-11-16       Impact factor: 4.030

8.  An analytical flow injection system to measure glutamate in microdialysis samples based on an enzymatic reaction and electrochemical detection.

Authors:  Alberto Morales-Villagrán; Cuauhtemoc Sandoval-Salazar; Laura Medina-Ceja
Journal:  Neurochem Res       Date:  2008-04-22       Impact factor: 3.996

9.  Real-time glutamate measurements in the putamen of awake rhesus monkeys using an enzyme-based human microelectrode array prototype.

Authors:  Michelle L Stephens; Francois Pomerleau; Peter Huettl; Greg A Gerhardt; Zhiming Zhang
Journal:  J Neurosci Methods       Date:  2009-10-20       Impact factor: 2.390

10.  Chronic second-by-second measures of L-glutamate in the central nervous system of freely moving rats.

Authors:  Erin C Rutherford; Francois Pomerleau; Peter Huettl; Ingrid Strömberg; Greg A Gerhardt
Journal:  J Neurochem       Date:  2007-08       Impact factor: 5.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.