Literature DB >> 21465093

Collection, storage, and electrophoretic analysis of nanoliter microdialysis samples collected from awake animals in vivo.

Meng Wang1, Neil D Hershey, Omar S Mabrouk, Robert T Kennedy.   

Abstract

Microdialysis sampling is an important tool for chemical monitoring in living systems. Temporal resolution is an important figure of merit that is determined by sampling frequency, assay sensitivity, and dispersion of chemical zones during transport from sampling device to fraction collector or analytical system. Temporal resolution has recently been improved by segmenting flow into plugs, so that nanoliter fractions are collected at intervals of 0.1-2 s, thus eliminating temporal distortion associated with dispersion in continuous flow. Such systems, however, have yet to be used with behaving subjects. Furthermore, long-term storage of nanoliter samples created by segmented flow has not been reported. In this work, we have addressed these challenges. A microdialysis probe was integrated to a plug generator that could be stably mounted onto behaving animals. Long-term storage of dialysate plugs was achieved by collecting plugs into high-purity perfluoroalkoxy tubes, placing the tube into hexane and then freezing at -80°C. Slow warming with even temperatures prevented plug coalescence during sample thawing. As a demonstration of the system, plugs were collected from the striatum of behaving rats using a 0.5-mm-long microdialysis probe. Resulting plugs were analyzed 1-4 days later by chip-based electrophoresis. To improve throughput of plug analysis over previous work, the speed of electrophoretic separation was increased by using forced air cooling and 1-butyl-2,3-dimethylimidazolium tetrafluoroborate as a separation buffer additive, allowing resolution of six neuroactive amino acids in 30 s. Concentration changes induced by K(+) microinjections were monitored with 10 s temporal resolution. The improvements reported in this work make it possible to apply segmented flow microdialysis to the study of behaving animals and enable experiments where the analytical system cannot be placed close to the animal.

Entities:  

Mesh:

Year:  2011        PMID: 21465093      PMCID: PMC3107505          DOI: 10.1007/s00216-011-4956-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  30 in total

1.  Surface-directed liquid flow inside microchannels.

Authors:  B Zhao; J S Moore; D J Beebe
Journal:  Science       Date:  2001-02-09       Impact factor: 47.728

2.  Glutamate measured by 6-s resolution brain microdialysis: capillary electrophoretic and laser-induced fluorescence detection application.

Authors:  S Tucci; P Rada; M J Sepúlveda; L Hernandez
Journal:  J Chromatogr B Biomed Sci Appl       Date:  1997-07-04

3.  Transient changes in nucleus accumbens amino acid concentrations correlate with individual responsivity to the predator fox odor 2,5-dihydro-2,4,5-trimethylthiazoline.

Authors:  B Jill Venton; Terry E Robinson; Robert T Kennedy
Journal:  J Neurochem       Date:  2005-11-21       Impact factor: 5.372

4.  Stability of GABA levels in CSF under various conditions of storage.

Authors:  M H Grossman; T A Hare; N V Manyam; B S Glaeser; J H Wood
Journal:  Brain Res       Date:  1980-01-20       Impact factor: 3.252

5.  High temporal resolution for in vivo monitoring of neurotransmitters in awake epileptic rats using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detection.

Authors:  Sandrine Parrot; Valérie Sauvinet; Véronique Riban; Antoine Depaulis; Bernard Renaud; Luc Denoroy
Journal:  J Neurosci Methods       Date:  2004-12-30       Impact factor: 2.390

6.  On-line coupling of microdialysis sampling with microchip-based capillary electrophoresis.

Authors:  Bryan H Huynh; Barbara A Fogarty; R Scott Martin; Susan M Lunte
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

7.  Application of rapid-sampling, online microdialysis to the monitoring of brain metabolism during aneurysm surgery.

Authors:  Robin Bhatia; Parastoo Hashemi; Ashfaq Razzaq; Mark C Parkin; Sarah E Hopwood; Martyn G Boutelle; Anthony J Strong
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

8.  Quantitative in vivo monitoring of primary amines in rat caudate nucleus using microdialysis coupled by a flow-gated interface to capillary electrophoresis with laser-induced fluorescence detection.

Authors:  M W Lada; R T Kennedy
Journal:  Anal Chem       Date:  1996-09-01       Impact factor: 6.986

9.  Separation of achiral and chiral analytes using polymeric surfactants with ionic liquids as modifiers in micellar electrokinetic chromatography.

Authors:  Simon M Mwongela; Abdulqawi Numan; Nicole L Gill; Rezik A Agbaria; Isiah M Warner
Journal:  Anal Chem       Date:  2003-11-15       Impact factor: 6.986

10.  Electrophoresis PDMS/glass chips with continuous on-chip derivatization and analysis of amino acids using naphthalene-2,3-dicarboxaldehyde as fluorogenic agent.

Authors:  O Yassine; P Morin; O Dispagne; L Renaud; L Denoroy; P Kleimann; K Faure; J-L Rocca; N Ouaini; R Ferrigno
Journal:  Anal Chim Acta       Date:  2008-01-10       Impact factor: 6.558

View more
  14 in total

1.  In vivo monitoring of serotonin in the striatum of freely moving rats with one minute temporal resolution by online microdialysis-capillary high-performance liquid chromatography at elevated temperature and pressure.

Authors:  Jing Zhang; Andrea Jaquins-Gerstl; Kathryn M Nesbitt; Sarah C Rutan; Adrian C Michael; Stephen G Weber
Journal:  Anal Chem       Date:  2013-09-24       Impact factor: 6.986

Review 2.  Nanomaterial-based electrochemical sensing of neurological drugs and neurotransmitters.

Authors:  Bankim J Sanghavi; Otto S Wolfbeis; Thomas Hirsch; Nathan S Swami
Journal:  Mikrochim Acta       Date:  2014-07-08       Impact factor: 5.833

Review 3.  A review of microdialysis coupled to microchip electrophoresis for monitoring biological events.

Authors:  Rachel A Saylor; Susan M Lunte
Journal:  J Chromatogr A       Date:  2015-01-10       Impact factor: 4.759

4.  Microfabrication and in Vivo Performance of a Microdialysis Probe with Embedded Membrane.

Authors:  Woong Hee Lee; Thitaphat Ngernsutivorakul; Omar S Mabrouk; Jenny-Marie T Wong; Colleen E Dugan; Samuel S Pappas; Hyeun Joong Yoon; Robert T Kennedy
Journal:  Anal Chem       Date:  2016-01-04       Impact factor: 6.986

5.  Investigation of signaling molecules and metabolites found in crustacean hemolymph via in vivo microdialysis using a multifaceted mass spectrometric platform.

Authors:  Shan Jiang; Zhidan Liang; Ling Hao; Lingjun Li
Journal:  Electrophoresis       Date:  2016-02-25       Impact factor: 3.535

Review 6.  Emerging trends in in vivo neurochemical monitoring by microdialysis.

Authors:  Robert T Kennedy
Journal:  Curr Opin Chem Biol       Date:  2013-07-12       Impact factor: 8.822

7.  A rotating operant chamber for use with microdialysis.

Authors:  Bart Degreef; Khanh T Ngo; Andrea Jaquins-Gerstl; Stephen G Weber
Journal:  J Neurosci Methods       Date:  2019-08-01       Impact factor: 2.390

8.  Online photolytic optical gating of caged fluorophores in capillary zone electrophoresis utilizing an ultraviolet light-emitting diode.

Authors:  Elyssia S Gallagher; Troy J Comi; Kevin L Braun; Craig A Aspinwall
Journal:  Electrophoresis       Date:  2012-08-22       Impact factor: 3.535

Review 9.  Use and Future Prospects of in Vivo Microdialysis for Epilepsy Studies.

Authors:  Alexander G Zestos; Hiram Luna-Munguia; William C Stacey; Robert T Kennedy
Journal:  ACS Chem Neurosci       Date:  2018-07-23       Impact factor: 4.418

10.  Reduced GABAergic transmission in the ventrobasal thalamus contributes to thermal hyperalgesia in chronic inflammatory pain.

Authors:  Chan Zhang; Rong-Xiang Chen; Yu Zhang; Jie Wang; Feng-Yu Liu; Jie Cai; Fei-Fei Liao; Fu-Qiang Xu; Ming Yi; You Wan
Journal:  Sci Rep       Date:  2017-02-02       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.