Literature DB >> 20447417

Collection of nanoliter microdialysate fractions in plugs for off-line in vivo chemical monitoring with up to 2 s temporal resolution.

Meng Wang1, Thomas Slaney, Omar Mabrouk, Robert T Kennedy.   

Abstract

An off-line in vivo neurochemical monitoring approach was developed based on collecting nanoliter microdialysate fractions as an array of "plugs" segmented by immiscible oil in a piece of Teflon tubing. The dialysis probe was integrated with the plug generator in a polydimethlysiloxane microfluidic device that could be mounted on the subject. The microfluidic device also allowed derivatization reagents to be added to the plugs for fluorescence detection of analytes. Using the device, 2 nL fractions corresponding to 1-20 ms sampling times depending upon dialysis flow rate, were collected. Because axial dispersion was prevented between them, each plug acted as a discrete sample collection vial and temporal resolution was not lost by mixing or diffusion during transport. In vitro tests of the system revealed that the temporal resolution of the system was as good as 2 s and was limited by mass transport effects within the dialysis probe. After collection of dialysate fractions, they were pumped into a glass microfluidic chip that automatically analyzed the plugs by capillary electrophoresis with laser-induced fluorescence at 50 s intervals. By using a relatively low flow rate during transfer to the chip, the temporal resolution of the samples could be preserved despite the relatively slow analysis time. The system was used to detect rapid dynamics in neuroactive amino acids evoked by microinjecting the glutamate uptake inhibitor l-trans-pyrrolidine-2,4-dicarboxylic acid (PDC) or K(+) into the striatum of anesthetized rats. The resulted showed increases in neurotransmitter efflux that reached a peak in 20 s for PDC and 13 s for K(+). Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20447417      PMCID: PMC2885530          DOI: 10.1016/j.jneumeth.2010.04.023

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  29 in total

1.  Surface-directed liquid flow inside microchannels.

Authors:  B Zhao; J S Moore; D J Beebe
Journal:  Science       Date:  2001-02-09       Impact factor: 47.728

2.  Glutamate measured by 6-s resolution brain microdialysis: capillary electrophoretic and laser-induced fluorescence detection application.

Authors:  S Tucci; P Rada; M J Sepúlveda; L Hernandez
Journal:  J Chromatogr B Biomed Sci Appl       Date:  1997-07-04

3.  Transient changes in nucleus accumbens amino acid concentrations correlate with individual responsivity to the predator fox odor 2,5-dihydro-2,4,5-trimethylthiazoline.

Authors:  B Jill Venton; Terry E Robinson; Robert T Kennedy
Journal:  J Neurochem       Date:  2005-11-21       Impact factor: 5.372

4.  High temporal resolution for in vivo monitoring of neurotransmitters in awake epileptic rats using brain microdialysis and capillary electrophoresis with laser-induced fluorescence detection.

Authors:  Sandrine Parrot; Valérie Sauvinet; Véronique Riban; Antoine Depaulis; Bernard Renaud; Luc Denoroy
Journal:  J Neurosci Methods       Date:  2004-12-30       Impact factor: 2.390

5.  On-line coupling of microdialysis sampling with microchip-based capillary electrophoresis.

Authors:  Bryan H Huynh; Barbara A Fogarty; R Scott Martin; Susan M Lunte
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

6.  Application of rapid-sampling, online microdialysis to the monitoring of brain metabolism during aneurysm surgery.

Authors:  Robin Bhatia; Parastoo Hashemi; Ashfaq Razzaq; Mark C Parkin; Sarah E Hopwood; Martyn G Boutelle; Anthony J Strong
Journal:  Neurosurgery       Date:  2006-04       Impact factor: 4.654

Review 7.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices.

Authors:  J Cooper McDonald; George M Whitesides
Journal:  Acc Chem Res       Date:  2002-07       Impact factor: 22.384

8.  Sampling and electrophoretic analysis of segmented flow streams using virtual walls in a microfluidic device.

Authors:  Gregory T Roman; Meng Wang; Kristin N Shultz; Colin Jennings; Robert T Kennedy
Journal:  Anal Chem       Date:  2008-10-03       Impact factor: 6.986

9.  Quantitative in vivo monitoring of primary amines in rat caudate nucleus using microdialysis coupled by a flow-gated interface to capillary electrophoresis with laser-induced fluorescence detection.

Authors:  M W Lada; R T Kennedy
Journal:  Anal Chem       Date:  1996-09-01       Impact factor: 6.986

10.  Cellular origins of endogenous amino acids released into the extracellular fluid of the rat striatum during severe insulin-induced hypoglycemia.

Authors:  S P Butcher; M Sandberg; H Hagberg; A Hamberger
Journal:  J Neurochem       Date:  1987-03       Impact factor: 5.372

View more
  23 in total

1.  Mass spectrometry "sensor" for in vivo acetylcholine monitoring.

Authors:  Peng Song; Neil D Hershey; Omar S Mabrouk; Thomas R Slaney; Robert T Kennedy
Journal:  Anal Chem       Date:  2012-05-24       Impact factor: 6.986

Review 2.  Electrochemical Analysis of Neurotransmitters.

Authors:  Elizabeth S Bucher; R Mark Wightman
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2015-05-04       Impact factor: 10.745

3.  Glutaraldehyde cross-linked glutamate oxidase coated microelectrode arrays: selectivity and resting levels of glutamate in the CNS.

Authors:  Jason J Burmeister; Verda A Davis; Jorge E Quintero; Francois Pomerleau; Peter Huettl; Greg A Gerhardt
Journal:  ACS Chem Neurosci       Date:  2013-05-09       Impact factor: 4.418

4.  In vivo solid-phase microextraction for monitoring intravenous concentrations of drugs and metabolites.

Authors:  Heather L Lord; Xu Zhang; F Marcel Musteata; Dajana Vuckovic; Janusz Pawliszyn
Journal:  Nat Protoc       Date:  2011-06-02       Impact factor: 13.491

Review 5.  A review of microdialysis coupled to microchip electrophoresis for monitoring biological events.

Authors:  Rachel A Saylor; Susan M Lunte
Journal:  J Chromatogr A       Date:  2015-01-10       Impact factor: 4.759

Review 6.  A review of flux considerations for in vivo neurochemical measurements.

Authors:  David W Paul; Julie A Stenken
Journal:  Analyst       Date:  2015-06-07       Impact factor: 4.616

7.  Microfabrication and in Vivo Performance of a Microdialysis Probe with Embedded Membrane.

Authors:  Woong Hee Lee; Thitaphat Ngernsutivorakul; Omar S Mabrouk; Jenny-Marie T Wong; Colleen E Dugan; Samuel S Pappas; Hyeun Joong Yoon; Robert T Kennedy
Journal:  Anal Chem       Date:  2016-01-04       Impact factor: 6.986

8.  Push-pull perfusion sampling with segmented flow for high temporal and spatial resolution in vivo chemical monitoring.

Authors:  Thomas R Slaney; Jing Nie; Neil D Hershey; Prasanna K Thwar; Jennifer Linderman; Mark A Burns; Robert T Kennedy
Journal:  Anal Chem       Date:  2011-06-07       Impact factor: 6.986

9.  Use of a corona discharge to selectively pattern a hydrophilic/hydrophobic interface for integrating segmented flow with microchip electrophoresis and electrochemical detection.

Authors:  Laura A Filla; Douglas C Kirkpatrick; R Scott Martin
Journal:  Anal Chem       Date:  2011-06-30       Impact factor: 6.986

Review 10.  Emerging trends in in vivo neurochemical monitoring by microdialysis.

Authors:  Robert T Kennedy
Journal:  Curr Opin Chem Biol       Date:  2013-07-12       Impact factor: 8.822

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.