Literature DB >> 12486518

Non-invasive determination of intraocular pressure in the rat eye. Comparison of an electronic tonometer (TonoPen), and a rebound (impact probe) tonometer.

David Goldblum1, Antti Ilmari Kontiola, Thom Mittag, Bin Chen, John Danias.   

Abstract

BACKGROUND: The reproducibility and accuracy of the induction/impact (I/I) probe device (rebound tonometer) and the TonoPen XL electronic tonometer were compared through the measurement of intraocular pressure (IOP) differences between contralateral rat eyes.
METHODS: IOP was measured in 18 female Wistar rats with variable, modest elevations of IOP in one eye. Mean IOP from five measurements on each of the 36 eyes was determined using the rebound tonometer, followed by the TonoPen XL. Following cannulation, true (manometrically determined) IOP was recorded with a calibrated pressure transducer. Differences between the operated and normal eye of each animal for each tonometric method of measurement were correlated with the true difference in IOP.
RESULTS: IOP differences between the operated and contralateral normal eye ranged from +5.9 to -1.7 mmHg (mean +1.7 mmHg) when measured by cannulation and from +7.2 to -1.4 mmHg (mean +2.4 mmHg) and +9.8 to -3.2 mmHg (mean +3.6 mmHg) when measured with the rebound tonometer and TonoPen XL respectively. Differences between eyes recorded by rebound tonometer ( y) correlated with those determined by cannulation ( x) in a linear fashion ( y=0.8243 x+1.0721; R(2)=0.6603). Correlation for the TonoPen XL was much weaker ( y=0.8675 x+2.1672; R(2)=0.2077). IOP measurements using the rebound tonometer did not differ significantly from true IOP, whereas TonoPen XL increasingly underestimated IOP with increasing IOP (9-20 mmHg).
CONCLUSION: The rebound tonometer displayed greater accuracy and less variability than TonoPen XL in measuring the IOP of the rat eye (range 9-20 mmHg).

Entities:  

Mesh:

Year:  2002        PMID: 12486518     DOI: 10.1007/s00417-002-0571-y

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  16 in total

1.  Comparation of the new rebound tonometer IOPen and the Goldmann tonometer, and their relationship to corneal properties.

Authors:  J Moreno-Montañés; I Gosende; J Caire; M García-Granero
Journal:  Eye (Lond)       Date:  2010-10-01       Impact factor: 3.775

Review 2.  Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure.

Authors:  A Cervino
Journal:  Br J Ophthalmol       Date:  2006-12       Impact factor: 4.638

3.  Reliability of Tonolab measurements in rats.

Authors:  Li-Fang Liu; Chu-Kai Huang; Ming-Zhi Zhang
Journal:  Int J Ophthalmol       Date:  2014-12-18       Impact factor: 1.779

4.  Differential susceptibility to experimental glaucoma among 3 mouse strains using bead and viscoelastic injection.

Authors:  Frances E Cone; Scott E Gelman; Janice L Son; Mary E Pease; Harry A Quigley
Journal:  Exp Eye Res       Date:  2010-06-26       Impact factor: 3.467

5.  Diadenosine tetraphosphate as a potential therapeutic nucleotide to treat glaucoma.

Authors:  Begoña Fonseca; Alejandro Martínez-Águila; María J Pérez de Lara; Jesús Pintor
Journal:  Purinergic Signal       Date:  2016-11-16       Impact factor: 3.765

6.  Intraocular pressure measurements in cattle, sheep, and goats with 2 different types of tonometers.

Authors:  Nina Peche; Johanna Corinna Eule
Journal:  Can J Vet Res       Date:  2018-07       Impact factor: 1.310

7.  Evaluation of rebound tonometry in red-eared slider turtles (Trachemys scripta elegans).

Authors:  Cherlene Delgado; Christoph Mans; Gillian J McLellan; Ellison Bentley; Kurt K Sladky; Paul E Miller
Journal:  Vet Ophthalmol       Date:  2013-11-06       Impact factor: 1.644

8.  Efficacy of TonoLab in detecting physiological and pharmacological changes in rat intraocular pressure: comparison of TonoPen and microneedle manometry.

Authors:  Masaaki Ohashi; Makoto Aihara; Tadashiro Saeki; Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2008-11-11       Impact factor: 2.447

9.  Electrophysiological deficits in the retina of the DBA/2J mouse.

Authors:  Joanna Harazny; Michael Scholz; Thomas Buder; Berthold Lausen; Jan Kremers
Journal:  Doc Ophthalmol       Date:  2009-09-17       Impact factor: 2.379

10.  Comparison of IOPen rebound tonometer with Goldmann applanation tonometer at different IOP levels.

Authors:  Fereydoun Farrahi; Farideh Sharifipour; Mohammad Malekahmadi; Bahman Cheraghian
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

View more