Literature DB >> 12465113

Band artifacts due to bulk motion.

Pippa Storey1, Qun Chen, Wei Li, Robert R Edelman, Pottumarthi V Prasad.   

Abstract

Band artifacts due to bulk motion were investigated in images acquired with fast gradient echo sequences. A simple analytical calculation shows that the width of the artifacts has a square-root dependence on the velocity of the imaged object, the time taken to acquire each line of k-space and the field of view in the phase-encoding direction. The theory furthermore predicts that the artifact width can be reduced using parallel imaging by a factor equal to the square root of the acceleration parameter. The analysis and results are presented for motion in the phase- and frequency-encoding directions and comparisons are made between sequential and centric ordering. The theory is validated in phantom experiments, in which bulk motion is simulated in a controlled and reproducible manner by rocking the scan table back and forth along the bore axis. Preliminary cardiac studies in healthy human volunteers show that dark bands may be observed in the endocardium in images acquired with nonsegmented fast gradient echo sequences. The fact that the position of the bands changes with the phase-encoding direction suggests that they may be artifacts due to motion of the heart walls during the image acquisition period. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12465113     DOI: 10.1002/mrm.10314

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies.

Authors:  E V R Di Bella; D L Parker; A J Sinusas
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

2.  High-resolution myocardial perfusion imaging at 3 T: comparison to 1.5 T in healthy volunteers.

Authors:  K Strach; C Meyer; D Thomas; C P Naehle; C Schmitz; H Litt; A Bernstein; B Cheng; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2007-02-16       Impact factor: 5.315

3.  High-resolution myocardial stress perfusion at 3 T in patients with suspected coronary artery disease.

Authors:  Carsten Meyer; Katharina Strach; Daniel Thomas; Harold Litt; Claas P Nähle; Klaus Tiemann; Ulrich Schwenger; Hans H Schild; Torsten Sommer
Journal:  Eur Radiol       Date:  2007-09-13       Impact factor: 5.315

4.  Small, short-duration, dobutamine-induced perfusion defects are not associated with adverse prognosis in intermediate-risk individuals receiving cardiovascular magnetic resonance stress imaging.

Authors:  Jennifer H Jordan; Jason C Haag; Timothy M Morgan; Sujethra Vasu; Brandon Stacey; Craig Hamilton; Killian Robinson; Dalane Kitzman; Vinay Thohan; William Gregory Hundley
Journal:  J Comput Assist Tomogr       Date:  2014 May-Jun       Impact factor: 1.826

Review 5.  Noninvasive imaging in coronary artery disease.

Authors:  Ran Heo; Ryo Nakazato; Dan Kalra; James K Min
Journal:  Semin Nucl Med       Date:  2014-09       Impact factor: 4.446

6.  First-pass myocardial perfusion MRI with reduced subendocardial dark-rim artifact using optimized Cartesian sampling.

Authors:  Zhengwei Zhou; Xiaoming Bi; Janet Wei; Hsin-Jung Yang; Rohan Dharmakumar; Reza Arsanjani; C Noel Bairey Merz; Debiao Li; Behzad Sharif
Journal:  J Magn Reson Imaging       Date:  2016-08-17       Impact factor: 4.813

7.  Steady-state first-pass perfusion (SSFPP): a new approach to 3D first-pass myocardial perfusion imaging.

Authors:  Shivraman Giri; Hui Xue; Andrei Maiseyeu; Randall Kroeker; Sanjay Rajagopalan; Richard D White; Sven Zuehlsdorff; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

Review 8.  Evaluation of the microcirculation: advances in cardiac magnetic resonance perfusion imaging.

Authors:  Amit R Patel; Frederick H Epstein; Christopher M Kramer
Journal:  J Nucl Cardiol       Date:  2008 Sep-Oct       Impact factor: 5.952

9.  Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

Authors:  Behzad Sharif; Rohan Dharmakumar; Troy LaBounty; Reza Arsanjani; Chrisandra Shufelt; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2013-09-12       Impact factor: 4.668

10.  Variability of myocardial perfusion dark rim Gibbs artifacts due to sub-pixel shifts.

Authors:  Pedro Ferreira; Peter Gatehouse; Peter Kellman; Chiara Bucciarelli-Ducci; David Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2009-05-27       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.