Literature DB >> 12438037

Pseudoenhancement of simulated renal cysts in a phantom using different multidetector CT scanners.

Cedela Abdulla1, Mannudeep K Kalra, Sanjay Saini, Michael M Maher, Aamir Ahmad, Elkan Halpern, Stuart G Silverman.   

Abstract

OBJECTIVE: We undertook this study to determine whether pseudoenhancement of renal cysts occurs on scans obtained with multidetector CT (MDCT) scanners and whether the effect is influenced by scanning parameters.
MATERIALS AND METHODS: A kidney phantom with varying attenuation was created to simulate different levels of renal parenchymal enhancement (150 and 250 H). Two water-filled cylinders simulating renal cysts-one with a 5-mm diameter and one with a 15-mm diameter-were suspended in the "kidney." After validating the pseudoenhancement effect produced in our phantom model with a single-detector helical CT scanner, we investigated the effect with matrix array and adaptive array MDCT scanners using detector configurations of 1.25 and 2.5 mm and beam pitches of 0.75:1.0 and 1.5:1.0 at an effective reconstructed slice thickness of approximately 3 mm. Three sets of experiments were performed at each setting, and mean cyst density was measured. Data were statistically analyzed using the Student's t test and multiple logistic regression analysis when appropriate.
RESULTS: Although pseudoenhancement was observed with MDCT scanners, the effect was statistically significant only for scans depicting the smaller cyst at a background renal density of 250 H on the matrix array MDCT. Modulation of scanning parameters did not alter these findings. Pseudoenhancement was significantly higher with the matrix array MDCT scanner than with the adaptive array MDCT scanner (p < 0.05).
CONCLUSION: In our phantom model, high levels of renal enhancement produced pseudoenhancement in small renal cysts with different models of MDCT scanners, irrespective of pitch or detector configuration.

Entities:  

Mesh:

Year:  2002        PMID: 12438037     DOI: 10.2214/ajr.179.6.1791473

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  11 in total

1.  Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms.

Authors:  Izuru Matsuda; Masaaki Akahane; Jiro Sato; Masaki Katsura; Shigeru Kiryu; Naoki Yoshioka; Akira Kunimatsu; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-02       Impact factor: 2.374

2.  Plaque imaging with CT coronary angiography: Effect of intra-vascular attenuation on plaque type classification.

Authors:  Erica Maffei; Chiara Martini; Teresa Arcadi; Alberto Clemente; Sara Seitun; Alessandra Zuccarelli; Tito Torri; Nico R Mollet; Alexia Rossi; Onofrio Catalano; Giancarlo Messalli; Filippo Cademartiri
Journal:  World J Radiol       Date:  2012-06-28

3.  Renal cyst pseudoenhancement at multidetector CT: what are the effects of number of detectors and peak tube voltage?

Authors:  Zhen J Wang; Fergus V Coakley; Yanjun Fu; Bonnie N Joe; Sven Prevrhal; Luis A Landeras; Emma M Webb; Benjamin M Yeh
Journal:  Radiology       Date:  2008-07-15       Impact factor: 11.105

4.  In vivo predictors of renal cyst pseudoenhancement at 120 kVp.

Authors:  Jeet Patel; Matthew S Davenport; Shokoufeh Khalatbari; Richard H Cohan; James H Ellis; Joel F Platt
Journal:  AJR Am J Roentgenol       Date:  2014-02       Impact factor: 3.959

Review 5.  Genitourinary applications of dual-energy CT.

Authors:  Terri J Vrtiska; Naoki Takahashi; Joel G Fletcher; Robert P Hartman; Lifeng Yu; Akira Kawashima
Journal:  AJR Am J Roentgenol       Date:  2010-06       Impact factor: 3.959

6.  Classification of noncalcified coronary atherosclerotic plaque components on CT coronary angiography: impact of vascular attenuation and density thresholds.

Authors:  E Maffei; K Nieman; C Martini; O Catalano; S Seitun; T Arcadi; R Malagò; A Rossi; A Clemente; N R Mollet; F Cademartiri
Journal:  Radiol Med       Date:  2011-11-17       Impact factor: 3.469

7.  Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

Authors:  Giorgio Ascenti; Achille Mileto; Bernhard Krauss; Michele Gaeta; Alfredo Blandino; Emanuele Scribano; Nicola Settineri; Silvio Mazziotti
Journal:  Eur Radiol       Date:  2013-03-12       Impact factor: 5.315

8.  The characterization of small hypoattenuating renal masses on contrast-enhanced CT.

Authors:  Neesha S Patel; Liina Poder; Zhen J Wang; Benjamin M Yeh; Aliya Qayyum; Hua Jin; Fergus V Coakley
Journal:  Clin Imaging       Date:  2009 Jul-Aug       Impact factor: 1.605

9.  Effect of thin overlapping reconstruction on the attenuation of small (< or = 3 cm) renal cysts in the nephrographic phase of MDCT: a phantom study.

Authors:  Sun Ho Kim; Seung Hyup Kim
Journal:  Korean J Radiol       Date:  2006 Oct-Dec       Impact factor: 3.500

Review 10.  Multidetector CT urography in imaging of the urinary tract in patients with hematuria.

Authors:  Michael M Maher; Mannudeep K Kalra; Stefania Rizzo; Peter R Mueller; Sanjay Saini
Journal:  Korean J Radiol       Date:  2004 Jan-Mar       Impact factor: 3.500