Literature DB >> 12414781

Fully automated detection of hepatitis C virus RNA in serum and whole-blood samples.

Harald H Kessler1, Alexandra M K Clarici, Evelyn Stelzl, Gerhard Mühlbauer, Elisabeth Daghofer, Brigitte I Santner, Egon Marth, Rudolf E Stauber.   

Abstract

In this study, we established a fully automated molecular assay for qualitative detection of hepatitis C virus (HCV) in serum and whole-blood samples and compared it with conventional molecular assays, including manual HCV RNA extraction protocols. Whole-blood samples were collected from patients with and without chronic HCV infection in EDTA tubes and nucleic acid stabilization tubes (NASTs). Prior to HCV RNA extraction, the HCV Internal Control (IC), derived from the COBAS AMPLICOR HCV test, version 2.0 (Roche Molecular Diagnostics), was added. The new assay was based on an automated extraction protocol on the MagNA Pure LC instrument (Roche Applied Science), followed by automated reverse transcription, amplification, hybridization, and detection on the Cobas Amplicor analyzer (Roche Molecular Diagnostics). The detection limit of the new assay was found to be similar to those of conventional molecular assays. In clinical samples, 100% agreement between the new assay and conventional methods was observed. The introduced amount of IC was detected in 45 of 45 serum samples, 41 of 45 EDTA tube whole-blood samples, and 43 of 45 NAST whole-blood samples. Retesting led to more frequent IC detection. The fully automated molecular assay was found to be suitable for detection of HCV RNA in different kinds of sample materials. It may be recommended for use in the high-throughput routine molecular diagnostic laboratory.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12414781      PMCID: PMC130092          DOI: 10.1128/cdli.9.6.1385-1388.2002

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  19 in total

1.  Peginterferon alfa-2a in patients with chronic hepatitis C.

Authors:  S Zeuzem; S V Feinman; J Rasenack; E J Heathcote; M Y Lai; E Gane; J O'Grady; J Reichen; M Diago; A Lin; J Hoffman; M J Brunda
Journal:  N Engl J Med       Date:  2000-12-07       Impact factor: 91.245

2.  Fully automated nucleic acid extraction: MagNA Pure LC.

Authors:  H H Kessler; G Mühlbauer; E Stelzl; E Daghofer; B I Santner; E Marth
Journal:  Clin Chem       Date:  2001-06       Impact factor: 8.327

3.  Effects of storage and type of blood collection tubes on hepatitis C virus level in whole blood samples.

Authors:  H H Kessler; E Stelzl; R B Raggam; J Haas; F Kirchmeir; K Hegenbarth; E Daghofer; B I Santner; E Marth; R E Stauber
Journal:  J Clin Microbiol       Date:  2001-05       Impact factor: 5.948

4.  Avoiding false positives with PCR.

Authors:  S Kwok; R Higuchi
Journal:  Nature       Date:  1989-05-18       Impact factor: 49.962

5.  Comparison of hepatitis B virus DNA extractions from serum by the QIAamp blood kit, GeneReleaser, and the phenol-chloroform method.

Authors:  A Kramvis; S Bukofzer; M C Kew
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

Review 6.  The polymerase chain reaction, a review of the practical limitations for human immunodeficiency virus diagnosis.

Authors:  J P Clewley
Journal:  J Virol Methods       Date:  1989-08       Impact factor: 2.014

7.  Evaluation of molecular parameters for routine assessment of viremia in patients with chronic hepatitis C who are undergoing antiviral therapy.

Authors:  H H Kessler; K Pierer; B I Santner; S K Vellimedu; E Stelzl; E Marth; P Fickert; R E Stauber
Journal:  J Hum Virol       Date:  1998 Jul-Aug

8.  Comparison of QIAamp HCV kit spin columns, silica beads, and phenol-chloroform for recovering human immunodeficiency virus type 1 RNA from plasma.

Authors:  R W Shafer; D J Levee; M A Winters; K L Richmond; D Huang; T C Merigan
Journal:  J Clin Microbiol       Date:  1997-02       Impact factor: 5.948

9.  Peginterferon alfa-2b plus ribavirin compared with interferon alfa-2b plus ribavirin for initial treatment of chronic hepatitis C: a randomised trial.

Authors:  M P Manns; J G McHutchison; S C Gordon; V K Rustgi; M Shiffman; R Reindollar; Z D Goodman; K Koury; M Ling; J K Albrecht
Journal:  Lancet       Date:  2001-09-22       Impact factor: 79.321

10.  Detection of replicative form of hepatitis C virus RNA in peripheral blood mononuclear cells.

Authors:  J T Wang; J C Sheu; J T Lin; T H Wang; D S Chen
Journal:  J Infect Dis       Date:  1992-11       Impact factor: 5.226

View more
  5 in total

1.  Comparison of automated and manual nucleic acid extraction methods for detection of enterovirus RNA.

Authors:  Julia H Knepp; Melissa A Geahr; Michael S Forman; Alexandra Valsamakis
Journal:  J Clin Microbiol       Date:  2003-08       Impact factor: 5.948

2.  Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens.

Authors:  Deborah Wilson; Belinda Yen-Lieberman; Udo Reischl; Ilka Warshawsky; Gary W Procop
Journal:  J Clin Microbiol       Date:  2004-12       Impact factor: 5.948

Review 3.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

4.  Reduced PCR sensitivity due to impaired DNA recovery with the MagNA Pure LC total nucleic acid isolation kit.

Authors:  Tim Schuurman; Alex van Breda; Richard de Boer; Mirjam Kooistra-Smid; Marcel Beld; Paul Savelkoul; René Boom
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

5.  Extraction of HCV-RNA from Plasma Samples: Development towards Semiautomation.

Authors:  Imran Amin; Tania Jabbar; Fawad Niazi; Muhammad Saeed Akhtar
Journal:  Int J Anal Chem       Date:  2015-03-19       Impact factor: 1.885

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.