Literature DB >> 12408474

A basic study of some normoxic polymer gel dosimeters.

Y De Deene1, C Hurley, A Venning, K Vergote, M Mather, B J Healy, C Baldock.   

Abstract

Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical formulation than the MAGIC gel.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12408474     DOI: 10.1088/0031-9155/47/19/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  A novel technique to enable experimental validation of deformable dose accumulation.

Authors:  Carolyn J Niu; Warren D Foltz; Michael Velec; Joanne L Moseley; Adil Al-Mayah; Kristy K Brock
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Influencing Factors on Reproducibility and Stability of MRI NIPAM Polymer Gel Dosimeter.

Authors:  Farideh Pak; Alireza Farajollahi; Ali Movafaghi; Alireza Naseri
Journal:  Bioimpacts       Date:  2013-07-14

3.  Optical scanner for 3D radiotherapy polymer gel dosimetry.

Authors:  Piotr Sobotka; Marek Kozicki; Piotr Maras; Ł Boniecki; K Kacperski; A W Domański
Journal:  Acta Phys Pol A       Date:  2012-11       Impact factor: 0.577

Review 4.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

5.  Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter.

Authors:  M Mahdavi; M KhademAbolfazli; S-R-M Mahdavi; Gh Ataei
Journal:  J Biomed Phys Eng       Date:  2013-06-01

6.  Optimization of the imaging protocol of an X-ray CT scanner for evaluation of normoxic polymer gel dosimeters.

Authors:  Brindha Subramanian; Paul B Ravindran; Clive Baldock
Journal:  J Med Phys       Date:  2006-04

7.  Determine the Dose Distribution Using Ultrasound Parameters in MAGIC-f Polymer Gels.

Authors:  Hossein Masoumi; Manijhe Mokhtari-Dizaji; Azim Arbabi; Mohsen Bakhshandeh
Journal:  Dose Response       Date:  2016-02-11       Impact factor: 2.658

8.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  Effect of composition interactions on the dose response of an N-isopropylacrylamide gel dosimeter.

Authors:  Yuan-Jen Chang; Bor-Tsung Hsieh
Journal:  PLoS One       Date:  2012-10-12       Impact factor: 3.240

10.  Indigenously developed multipurpose acrylic head phantom for verification of IMRT using film and gel dosimetry.

Authors:  N Gopishankar; S Vivekanandhan; G K Rath; M A Laviraj; S Senthilkumaran; S S Kale; S Thulkar; R K Bisht; V Subramani
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

View more