Literature DB >> 25505746

Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter.

M Mahdavi1, M KhademAbolfazli2, S-R-M Mahdavi3, Gh Ataei4.   

Abstract

BACKGROUND: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.
OBJECTIVE: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.
METHODS: In this work the normoxic polymer gel dosimeter MAGICA tissue-equivalence was first theoretically verified using MCNPX Monte Carlo code and experimentally by percentage depth dose curves within the gel medium. Then gold nanoparticles (GNPs) of 50nm diameter with different concentrations of 0.1mM, 0.2mM, and 0.4mM were embedded in MAGICA gel and irradiated by 18MV photon beam.
RESULTS: Experimental results have shown dose increase of 10%, 2% and 4%   in 0.1mM, 0.2mM and 0.4mM concentrations, respectively. Simulation results had good agreement in the optimum concentration of 0.1mM. The largest error between experimental and simulation results was equal to 9.28% stood for 0.4mM concentration.
CONCLUSION: The results showed that the optimum concentration of gold nanoparticles to achieve maximum absorbed dose in both experimental and simulation was 0.1 mM and so it can be used for clinical studies.

Entities:  

Keywords:  Gold nanoparticles; Percentage depth dose; Polymer gel dosimeter

Year:  2013        PMID: 25505746      PMCID: PMC4204492     

Source DB:  PubMed          Journal:  J Biomed Phys Eng        ISSN: 2251-7200


  5 in total

1.  Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: II. Analysis of B1-field inhomogeneity.

Authors:  Y De Deenet; C De Wagter; W De Neve; E Achten
Journal:  Phys Med Biol       Date:  2000-07       Impact factor: 3.609

2.  Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: I. Analysis and compensation of eddy currents.

Authors:  Y De Deene; C De Wagter; W De Neve; E Achten
Journal:  Phys Med Biol       Date:  2000-07       Impact factor: 3.609

3.  Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning.

Authors:  Y De Deene; C De Wagter
Journal:  Phys Med Biol       Date:  2001-10       Impact factor: 3.609

4.  A basic study of some normoxic polymer gel dosimeters.

Authors:  Y De Deene; C Hurley; A Venning; K Vergote; M Mather; B J Healy; C Baldock
Journal:  Phys Med Biol       Date:  2002-10-07       Impact factor: 3.609

5.  Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere.

Authors:  P M Fong; D C Keil; M D Does; J C Gore
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.