Rapid radiographic film calibration for IMRT verification using automated MLC fields.

Nathan L Childress1, Lei Dong, Isaac I Rosen.   

Abstract

A method for measuring a film sensitometric curve using a single sheet of film exposed with a two field step-and-shoot MLC treatment was developed and tested with Kodak XV2 and EDR2 films. With this technique a film sensitometric curve can be completed in only 10 minutes, making it practical to generate new film calibrations daily. This method is applicable to film calibrations for all purposes, but is particularly useful in IMRT treatment verification due to the method's use of small fields. This method agrees with the traditional large-field multifilm calibration within 0.5% and will produce sensitometric curves with errors less than 1% throughout the dose range, including uncertainties in dose delivery, film response, and optical density measurements. OD values for XV2 and EDR2 films were consistent in the middle of exposure areas at high depths, but the XV2 film penumbra regions showed large amounts of over-response as the calibration depth increased. If XV2 film is used for IMRT treatment verification, it is necessary to reduce the fluence of low energy photons in areas around the film by using thin lead shields. EDR2 film was shown to have minimal energy dependence, as it accurately represented penumbra areas and yielded identical sensitometric curves generated with 6 and 18 MV photons. However, its darker tint may make it more sensitive to scanning laser film digitizers' horizontal nonuniformities. This single film method proved to be superior to the traditional calibration method and allows fast daily calibrations of films for highly accurate IMRT delivery verifications.

Entities:  

Mesh:

Year:  2002        PMID: 12408313     DOI: 10.1118/1.1509441

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  A calibration method for patient specific IMRT QA using a single therapy verification film.

Authors:  Arvind Kumar Shukla; Arun S Oinam; Sanjeev Kumar; I S Sandhu; S C Sharma
Journal:  Rep Pract Oncol Radiother       Date:  2013-05-24

2.  Dose distribution verifications of IMRT for NPC.

Authors:  Qin Li; Liang Li; Jun Han; Zhiwen Liang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2009-10-11

3.  Transit dosimetry in dynamic IMRT with an a-Si EPID.

Authors:  Mahsheed Sabet; Pejman Rowshanfarzad; Fred W Menk; Peter B Greer
Journal:  Med Biol Eng Comput       Date:  2014-05-31       Impact factor: 2.602

4.  Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry.

Authors:  Jason E Matney; Brent C Parker; Daniel W Neck; Greg Henkelmann; Isaac I Rosen
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

5.  Validation of physics improvements for IMRT with a commercial treatment-planning system.

Authors:  Patrick Cadman; Todd McNutt; Karl Bzdusek
Journal:  J Appl Clin Med Phys       Date:  2005-05-19       Impact factor: 2.102

6.  Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters.

Authors:  Shu-Hui Hsu; Ravi Kulasekere; Peter L Roberson
Journal:  J Appl Clin Med Phys       Date:  2010-08-05       Impact factor: 2.102

7.  Use of a matchline dosimetry analysis tool (MDAT) to quantify dose homogeneity in the region between abutting tangential and supraclavicular radiation fields.

Authors:  Kenneth L Homann; B Earl Gates; Mohammad Salehpour; David S Followill; Steven M Kirsner; R Allen White; Thomas A Buchholz; Karl L Prado
Journal:  J Appl Clin Med Phys       Date:  2010-07-27       Impact factor: 2.102

8.  Comparative Study between Measurement Data and Treatment Planning System (TPS) in Small Fields for High Energy Photon Beams.

Authors:  Khaled El Shahat; Aziza El Saeid; Ehab Attalla; Adel Yassin
Journal:  ISRN Oncol       Date:  2014-05-06

9.  Radiographic film dosimetry for IMRT fields in the nearsurface buildup region.

Authors:  Peter L Roberson; Jean M Moran; Ravi Kulasekere
Journal:  J Appl Clin Med Phys       Date:  2008-10-24       Impact factor: 2.102

10.  Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification.

Authors:  Ravi Kulasekere; Jean M Moran; Benedick A Fraass; Peter L Roberson
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.