| Literature DB >> 12383048 |
Miguel L Rodríguez1, Carlos E deAlmeida.
Abstract
Monte Carlo calculations of the absorbed dose at various points of a brachytherapy anthropomorphic phantom are presented. The phantom walls and internal structures are made of polymethylmethacrylate and its external shape was taken from a female Alderson phantom. A complete Fletcher-Green type applicator with the uterine tandem was fixed at the bottom of the phantom reproducing a typical geometrical configuration as that attained in a gynecological brachytherapy treatment. The dose rate produced by an array of five (137)Cs CDC-J type sources placed in the applicator colpostats and the uterine tandem was evaluated by Monte Carlo simulations using the code PENELOPE at three points: point A, the rectum, and the bladder. The influence of the applicator in the dose rate was evaluated by comparing Monte Carlo simulations of the sources alone and the sources inserted in the applicator. Differences up to 56% in the dose may be observed for the two cases in the planes including the rectum and bladder. The results show a reduction of the dose of 15.6%, 14.0%, and 5.6% in the rectum, bladder, and point A respectively, when the applicator wall and shieldings are considered.Entities:
Mesh:
Year: 2002 PMID: 12383048 PMCID: PMC5724533 DOI: 10.1120/jacmp.v3i4.2552
Source DB: PubMed Journal: J Appl Clin Med Phys ISSN: 1526-9914 Impact factor: 2.102
Figure 1The anthropomorphic pelvic phantom and the coordinate system used for the Monte Carlo simulation.
Figure 2Internal structure of the colpostat. The box at left shows transversal planes taken along the shieldings (not specified dimensions are in cm).
Figure 33D rendered views of the geometry of the applicator and tandem created for simulation. Cuts have been made at planes containing the sources in order to illustrate as they are inserted in the colpostats and tandem.
Locations of the relevant point of interest relative to the system of coordinates defined for simulation.
| Point of interest |
|
|
|
|---|---|---|---|
| Point A |
| 3.75 | 0.5 |
| Rectum | 0.0 | 0.0 |
|
| Bladder | 0.0 |
| 3.1 |
Figure 4The isodose curves at plane . The dose rate values are in cGy/h.
Figure 5The isodose curves at plane . The dose rate values are in cGy/h.
Figure 6The isodose curves at plane . The dose rate values are in cGy/h.
Results of dose rate evaluated at the three clinical points by the Monte Carlo method with and without the influence of the applicator.
| Site | Dose rate (cGy/h) | ||
|---|---|---|---|
| Sources only | Applicator | Ratio (sources only/applicator) | |
| Point A |
|
| 1.059 |
| Rectum |
|
| 1.184 |
| Bladder |
|
| 1.163 |