Literature DB >> 2380082

Dose calculations about shielded gynecological colpostats.

J F Williamson1.   

Abstract

Although shielded gynecological colpostats have been shown experimentally to reduce doses to bladder and rectal tissue by as much as 50%, nearly all previously described dose computation algorithms ignore applicator heterogeneities. We describe the use of realistic Monte Carlo calculations to study the dosimetric effects of applicator structure. Use of sophisticated solid modeling techniques allows the complex internal structure of two commercially-available Fletcher-Suit colpostats, as well as that of 226Ra or 137Cs tubes, to be accurately simulated. Our results show significant differences among these source-applicator combinations. In addition, a novel dose computation algorithm for efficiently estimating absorbed dose near shielded applicators is described. Our approach is based upon empirical separation of primary- and scatter-dose components. The algorithm requires a small base of Monte Carlo-generated data, reproduces the Monte Carlo dose estimates within 3%, and is faster than Monte Carlo by a factor of 15,000. The scatter-separation method has the potential to make accurate dose estimates to bladder, rectum, tumor, and vagina available for clinical treatment planning and for extraction of more meaningful dose-response curves from clinical data.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2380082     DOI: 10.1016/0360-3016(90)90150-i

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  3 in total

1.  Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method.

Authors:  Miguel L Rodríguez; Carlos E deAlmeida
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

2.  Comparison of a 3-D multi-group SN particle transport code with Monte Carlo for intracavitary brachytherapy of the cervix uteri.

Authors:  Kent A Gifford; Todd A Wareing; Gregory Failla; John L Horton; Patricia J Eifel; Firas Mourtada
Journal:  J Appl Clin Med Phys       Date:  2009-12-03       Impact factor: 2.102

3.  Impact of the vaginal applicator and dummy pellets on the dosimetry parameters of Cs-137 brachytherapy source.

Authors:  Sedigheh Sina; Reza Faghihi; Ali S Meigooni; Simin Mehdizadeh; M Amin Mosleh Shirazi; Mehdi Zehtabian
Journal:  J Appl Clin Med Phys       Date:  2011-05-19       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.