Literature DB >> 12381691

Influence of patient age on normalized effective doses calculated for CT examinations.

A Khursheed1, M C Hillier, P C Shrimpton, B F Wall.   

Abstract

Monte Carlo simulations of CT examinations have been performed to estimate effective doses, normalized to axial air kerma, for six mathematical phantoms representing ages from newborn to adult, and for three CT scanner models covering a range of designs. Organ doses were calculated for CT exposures of contiguous, 1 cm wide, transverse slices in each phantom and summed to give normalized effective doses for scans of four regions of the trunk and head. In all cases an inverse trend is observed between normalized effective dose and phantom age, with the dose to the newborn from head and neck scans being 2.2-2.5 times higher than that to the adult, depending on scanner model. Corresponding increases for scans of the trunk region are more variable between scanners and range from a factor of 1.3 to 2.4. If typical clinical exposure conditions for adults are also utilized for children, then, for example, the effective dose to the newborn from a chest scan could be above 15 mSv. It is concluded that CT has the potential to deliver significantly greater radiation doses to children than to adults and in view of their greater susceptibility to radiation effects, special efforts should be made in clinical practice to reduce doses to children by the use of size-specific scan protocols.

Entities:  

Mesh:

Year:  2002        PMID: 12381691     DOI: 10.1259/bjr.75.898.750819

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  49 in total

1.  Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality.

Authors:  Claude Bertrand Nauer; Christoph Zubler; Christian Weisstanner; Christof Stieger; Pascal Senn; Andreas Arnold
Journal:  Neuroradiology       Date:  2011-09-23       Impact factor: 2.804

2.  A pediatric CT dose and risk estimator.

Authors:  Adam M Alessio; Grace S Phillips
Journal:  Pediatr Radiol       Date:  2010-07-11

3.  Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008.

Authors:  P Catuzzo; S Aimonetto; F Zenone; G Fanelli; P Marchisio; T Meloni; M Pasquino; S Tofani
Journal:  Br J Radiol       Date:  2010-12       Impact factor: 3.039

4.  Updated estimates of typical effective doses for common CT examinations in the UK following the 2011 national review.

Authors:  Paul C Shrimpton; Jan T M Jansen; John D Harrison
Journal:  Br J Radiol       Date:  2015-11-06       Impact factor: 3.039

5.  Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

Authors:  Mariana Baptista; Salvatore Di Maria; Sandra Vieira; Joana Santos; Joana Pereira; Miguel Pereira; Pedro Vaz
Journal:  Radiat Environ Biophys       Date:  2018-11-03       Impact factor: 1.925

6.  Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy.

Authors:  Christoph M Heyer; Stefan P Lemburg; Thomas Kagel; Klaus-Michael Mueller; Thomas G Nuesslein; Christian H L Rieger; Volkmar Nicolas
Journal:  Eur Radiol       Date:  2005-01-26       Impact factor: 5.315

7.  Low-dose temporal bone CT in infants and young children: effective dose and image quality.

Authors:  C B Nauer; A Rieke; C Zubler; C Candreia; A Arnold; P Senn
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

8.  Comparison of Haller index values calculated with chest radiographs versus CT for pectus excavatum evaluation.

Authors:  Geetika Khanna; Alok Jaju; Steven Don; Tim Keys; Charles F Hildebolt
Journal:  Pediatr Radiol       Date:  2010-05-15

9.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

10.  Patient-specific dose estimation for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.