Literature DB >> 12361157

Are all aberrations equal?

Raymond A Applegate1, Edwin J Sarver, Vic Khemsara.   

Abstract

PURPOSE: To determine for a fixed RMS error (25 microm, over a 6-mm pupil) how each mode of the normalized Zernike polynomial (second through the fourth radial order) affects high and low contrast logMAR visual acuity.
METHODS: Three healthy volunteers served as subjects. CTView was used to generate optically aberrated logMAR charts. Accommodation was paralyzed and pupils dilated. The foveal achromatic axis of the eye was aligned to a 3-mm pupil and the eye was optimally refracted. Aberrated acuity charts were read until five letters were missed. Data were normalized for each subject to the acuity obtained by reading unaberrated charts and plotted as letters lost as a function of Zernike mode.
RESULTS: Defocus (Z2(0)) decreased letter acuity more than astigmatism (Z2(2), Z2(-2)). Coma (Z3(1), Z3(-1)) decreased acuity more than trefoil (Z3(3), Z3(-3)). Spherical aberration (Z4(0)) and secondary astigmatism (Z2(2), Z4(-2)) decreased acuity much more than quadrafoil (Z4(4), Z4(-4)).
CONCLUSIONS: 1. For an equal amount of RMS error not all coefficients of the Zernike polynomial induce equivalent losses in high and low contrast logMAR acuity. 2. Wavefront error concentrated near the center of the pyramid adversely affects visual acuity more than modes near the edge of the pyramid. 3. Large changes in chart appearance are not reflected in equally large decreases in visual performance (ie, subjects could correctly identify highly aberrated letters). 4. Interactions between modes complicate weighting each Zernike mode for visual impact.

Entities:  

Mesh:

Year:  2002        PMID: 12361157     DOI: 10.3928/1081-597X-20020901-12

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  58 in total

Review 1.  [Current state of wavefront guided corneal surgery to correct refraction disorders].

Authors:  T Kohnen; J Bühren
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

2.  Analysis of the optical quality by determining the modulation transfer function for anterior corneal surface in myopes.

Authors:  Yan-Zhen Zheng; Yan-Peng Chen; Yan Qiu; Guo-Guang Zhai; Yao-Yu Li
Journal:  Int J Ophthalmol       Date:  2012-04-18       Impact factor: 1.779

3.  Comparison of higher-order aberration and optical quality after Epi-LASIK and LASIK for myopia.

Authors:  Xiaoyan Yang; Yan Wang; Kanxing Zhao; Lihua Fang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-05-07       Impact factor: 3.117

4.  Impact of Zernike-fit error on simulated high- and low-contrast acuity in keratoconus: implications for using Zernike-based corrections.

Authors:  Jason D Marsack; Konrad Pesudovs; Edwin J Sarver; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2006-04       Impact factor: 2.129

Review 5.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part II: examples].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-11       Impact factor: 1.059

6.  [Application of wavefront analysis in clinical and scientific settings. From irregular astigmatism to aberrations of a higher order--Part I: Basic principles].

Authors:  J Bühren; T Kohnen
Journal:  Ophthalmologe       Date:  2007-10       Impact factor: 1.059

7.  Effect of sampling on real ocular aberration measurements.

Authors:  Lourdes Llorente; Susana Marcos; Carlos Dorronsoro; Stephen A Burns
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-09       Impact factor: 2.129

8.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

9.  Optimizing wavefront-guided corrections for highly aberrated eyes in the presence of registration uncertainty.

Authors:  Yue Shi; Hope M Queener; Jason D Marsack; Ayeswarya Ravikumar; Harold E Bedell; Raymond A Applegate
Journal:  J Vis       Date:  2013-06-11       Impact factor: 2.240

10.  Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Harold E Bedell; Yue Shi; Raymond A Applegate
Journal:  J Vis       Date:  2013-11-26       Impact factor: 2.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.