Literature DB >> 12355304

Pull-out and shear failure strengths of arthroscopic meniscal repair systems.

Stephen R Fisher1, David C Markel, Jon D Koman, Theresa S Atkinson.   

Abstract

Meniscal repair is common and recommended in young patients. Suture techniques and fixation devices were developed for stronger, more facile repairs. Three devices (T-Fix, Meniscal Staple, Meniscus Arrow) were biomechanically compared to horizontal PDS suture. Peripheral tears were created in porcine menisci and repaired using the manufacturer's technique. An Instron was used to distract the menisci at 50 mm/min in axial-pullout and longitudinal shear loads. Load to failure curves and peak failure loads were noted. Load to failure in axially loaded pull-out mode was: Staple, 4.195+/-3.70 N; Arrow, 39.755+/-11.37 N; T-Fix, 45.892+/-13.99 N; Suture, 107.65+/-22.37 N. Analysis of variance with post hoc testing revealed Staple failure at lower load than all devices and Suture failure at higher loads than all devices; Arrow and T-Fix were similar. The data varied significantly from that obtained in shear. Shear loads to failure were: Staple, 8.39+/-8.62 N; Arrow, 27.67+/-14.33 N; T-Fix, 57.47+/-17.05 N; Suture, 64.15+/-17.05 N. Analysis of variance, power analysis, and pair-wise multiple comparisons revealed significant differences between: Suture and Staple, Suture and Arrow, and T-Fix and Staple. No differences were noted between Suture and T-Fix, T-Fix and Arrow, or Arrow and Staple. In pullout, Suture and T-Fix maintained better apposition at low loads. As load increased, the menisci separated until device failure. Arrows allowed low load separation but held tissue until failure. Staples failed at low load. For shear, the menisci attempted to reorient parallel to the force. The devices failed in a pull-slide pattern. Suture failed by pull-through. Meniscal repair devices are easy to use and may provide resistance to shear and pull out. The resistance to pullout loads was very different than the resistance to longitudinal shear loads.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12355304     DOI: 10.1007/s00167-002-0295-x

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  9 in total

1.  A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

Authors:  Thore Zantop; Anne Kathleen Eggers; Volker Musahl; Andre Weimann; Joachim Hassenpflug; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-12-19       Impact factor: 4.342

2.  Horizontal suture placement influences meniscal repair fixation strength.

Authors:  Yavuz Kocabey; Omer Taser; John Nyland; Haluk Ince; Feyzi Sahin; Emin Sunbuloglu; Gokhan Baysal
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-07       Impact factor: 4.342

3.  Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study.

Authors:  Yavuz Kocabey; Omer Taşer; Onur Hapa; Aycan Güçlü; Ergun Bozdag; Emin Sünbüloglu; Mahmutnedim Doral
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-03       Impact factor: 4.342

4.  Histoacryl glue in meniscal repairs (a biomechanical study).

Authors:  Irfan Ayan; Mehmet Colak; Ulku Comelekoglu; Abtullah Milcan; Oya Ogenler; Volkan Oztuna; Fehmi Kuyurtar
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

5.  A novel technique for arthroscopic reduction and repair of a bucket-handle meniscal tear.

Authors:  Jung-Ro Yoon; Nasir Muzaffar; Jong-Woo Kang; Hong Chul Lim; Ji-Hoon Bae; Kyung Wook Nha
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-31       Impact factor: 4.342

6.  Biomechanical evaluation of arthroscopic all-inside meniscus repairs.

Authors:  Taner Gunes; Bora Bostan; Mehmet Erdem; Murat Asci; Cengiz Sen; Mehmet Halidun Kelestemur
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

Review 7.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

Authors:  Daniel M Buckland; Patrick Sadoghi; Matthias D Wimmer; Patrick Vavken; Geert I Pagenstert; Victor Valderrabano; Claudio Rosso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

Review 8.  Inside-Out Approach to Meniscus Repair: Still the Gold Standard?

Authors:  Erick M Marigi; Sara E Till; Jory N Wasserburger; Anna K Reinholz; Aaron J Krych; Michael J Stuart
Journal:  Curr Rev Musculoskelet Med       Date:  2022-04-30

9.  Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears.

Authors:  Charles Milchteim; Eric A Branch; Ty Maughon; Jay Hughey; Adam W Anz
Journal:  Orthop J Sports Med       Date:  2016-04-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.