Literature DB >> 22484371

Horizontal suture placement influences meniscal repair fixation strength.

Yavuz Kocabey1, Omer Taser, John Nyland, Haluk Ince, Feyzi Sahin, Emin Sunbuloglu, Gokhan Baysal.   

Abstract

PURPOSE: This in vitro biomechanical study investigated the influence of horizontal suture placement distance from the medial meniscal lesion repair site on fixation characteristics during submaximal cyclic and load to failure test conditions.
METHODS: Eighteen cadaveric (20-45 years of age) medial menisci with intact joint capsules were harvested within 24-48 h after death and divided into two groups of 9 specimens each for biomechanical testing. A 2.0-cm-long antero-posterior vertical longitudinal lesion was created with a #15 scalpel 2.0-3.0 mm from the outer edge of each meniscus. Menisci were repaired using #2-0 suture material with two horizontal suture loops placed either 1.0 mm (Group 1) or 3.0 mm (Group 2) from the lesion site. Following repair, the lesion was extended completely through the meniscal horns so that no tissue secured the repair, only the two horizontal suture loops representing a "worst-case" testing scenario. Following repair, specimens were placed in a servo hydraulic device using a pair of 1.2-mm-diameter steel wire loops and underwent submaximal cyclic loading between 5 and 50 N (1 Hz) for 500 cycles prior to load to failure testing (5 mm/min crosshead speed, 20 Hz data collection). An alpha level of P < 0.05 was selected to indicate statistical significance.
RESULTS: Five of nine (55.6 %) Group 1 specimens did not complete submaximal cyclic testing. All Group 2 specimens completed submaximal cyclic testing (Fisher's exact test P = 0.029). Statistically significant mean group differences were not observed for displacement during submaximal cyclic loading (Group 1 = 5.0 ± 1.5 mm and Group 2 = 5.7 ± 1.6 mm) or for construct stiffness during load to failure testing (Group 1 = 50.1 ± 6.3 N/mm and Group 2 = 52.6 ± 11.9 N/mm). Group 2 displayed greater mean load at failure (112.1 ± 40.8 N vs. 72.7 ± 11.2 N, P = 0.02) and mean displacement at failure (11.1 ± 2.2 mm vs. 7.6 ± 1.4 mm, P = 0.03) than Group 1.
CONCLUSIONS: Horizontal sutures placed slightly farther away from the meniscus lesion displayed superior repair fixation than sutures placed closer to the lesion. The superior biomechanical meniscal repair fixation provided by capturing greater tissue volume may enable safe earlier participation in functional exercise activities. Studies are needed to verify these findings in vivo.

Entities:  

Mesh:

Year:  2012        PMID: 22484371     DOI: 10.1007/s00167-012-1995-5

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  22 in total

1.  A biomechanical study of four different meniscal repair systems, comparing pull-out strengths and gapping under cyclic loading.

Authors:  I D McDermott; S W Richards; P Hallam; S Tavares; J R Lavelle; A A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-11-26       Impact factor: 4.342

2.  Pull-out and shear failure strengths of arthroscopic meniscal repair systems.

Authors:  Stephen R Fisher; David C Markel; Jon D Koman; Theresa S Atkinson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-06-05       Impact factor: 4.342

3.  The movements of bones and joints; the synovial fluid and its assistants.

Authors:  M A MacCONAILL
Journal:  J Bone Joint Surg Br       Date:  1950-05

4.  Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.

Authors:  F Alan Barber; Morley A Herbert; F Alexander Schroeder; Jorge Aziz-Jacobo; Michael J Sutker
Journal:  Arthroscopy       Date:  2009-09       Impact factor: 4.772

5.  Meniscal tear biomechanics: loads across meniscal tears in human cadaveric knees.

Authors:  David P Richards; F Alan Barber; Morley A Herbert
Journal:  Orthopedics       Date:  2008-04       Impact factor: 1.390

6.  Stabilizing mechanisms of the loaded and unloaded knee joint.

Authors:  H H Hsieh; P S Walker
Journal:  J Bone Joint Surg Am       Date:  1976-01       Impact factor: 5.284

7.  Mechanical changes in the knee after meniscectomy.

Authors:  W R Krause; M H Pope; R J Johnson; D G Wilder
Journal:  J Bone Joint Surg Am       Date:  1976-07       Impact factor: 5.284

8.  Meniscal tears: the effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. A preliminary report.

Authors:  M E Baratz; F H Fu; R Mengato
Journal:  Am J Sports Med       Date:  1986 Jul-Aug       Impact factor: 6.202

9.  Meniscal repair. An arthroscopic technique.

Authors:  F A Barber; R G Stone
Journal:  J Bone Joint Surg Br       Date:  1985-01

10.  Amount of meniscal resection after failed meniscal repair.

Authors:  Nicolas Pujol; Olivier Barbier; Philippe Boisrenoult; Philippe Beaufils
Journal:  Am J Sports Med       Date:  2011-04-06       Impact factor: 6.202

View more
  6 in total

1.  The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus.

Authors:  Ashraf Abdelkafy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-12       Impact factor: 4.342

2.  The effect of inclination angle on the strength of vertical mattress configuration for meniscus repair.

Authors:  Mehmet Erduran; Onur Hapa; Baran Şen; Yavuz Kocabey; Diler Erdemli; Mehran Aksel; Hasan Havitçioğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-09       Impact factor: 4.342

Review 3.  Meniscus tear surgery and meniscus replacement.

Authors:  Javier Vaquero; Francisco Forriol
Journal:  Muscles Ligaments Tendons J       Date:  2016-05-19

4.  Short- to mid-term results of arthroscopic meniscal repair of long vertical longitudinal tears using combined cruciate and horizontal suture techniques: a retrospective study.

Authors:  Ashraf Abdelkafy
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-05-28

Review 5.  Top orthopedic sports medicine procedures.

Authors:  Sebastiano Vasta; Rocco Papalia; Erika Albo; Nicola Maffulli; Vincenzo Denaro
Journal:  J Orthop Surg Res       Date:  2018-07-31       Impact factor: 2.359

6.  Evaluation of Midterm Clinical and Radiographic Outcomes of Arthroscopically Repaired Vertical Longitudinal and Bucket-Handle Lateral Meniscal Tears.

Authors:  Erdal Uzun; Abdulhamit Misir; Turan Bilge Kizkapan; Mustafa Ozcamdalli; Soner Akkurt; Ahmet Guney
Journal:  Orthop J Sports Med       Date:  2019-05-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.