Abstract

Viper is a new device for arthroscopically all-inside meniscal repairing. In previous studies about Viper device, procedures were not applied arthroscopically despite this device has been designed for arthroscopic application. In this study, we evaluated primary fixation strength of arthroscopically applied meniscal repair using Viper device to obtain better clinical relevance. Two centimeter in length meniscal tear 2-3 mm far from periferic edge of medial meniscus of 50 calves were created arthroscopically. The menisci were divided into five groups including 10 menisci in each. In group 1, tears were repaired by outside-in vertical loop suture technique with No: 0 PDS. Tears were fixed by all-inside vertical suture by using Viper device with No: 0 PDS in group 2. In meniscal implant groups, RapidLoc, H-Fix, and Clearfix were applied in groups 3,4, and 5, respectively. Primary fixation strength of repairing techniques were evaluated with bio-mechanical testing machine. Fixation strengths determined in groups 1 and 2 were detected as 145 +/- 13 and 136 +/- 33 N, respectively. There was no difference in pull-out strength between groups 1 and 2. Fixation strengths in these two groups were significantly higher compared to groups 3, 4, and 5. There was no significant difference between group 3 (33 +/- 6 N) and 5 (28 +/- 6 N) in terms of fixation strengths whereas fixation strengths of these two groups were significantly higher compared to group 4 (20 +/- 3 N) (P = 0.005, P = 0.018, respectively). All-inside vertical suture technique using Viper device revealed comparable primary fixation strength with outside-in vertical suture technique for meniscal repair. We suggest that the Viper device is safe and reliable for meniscal repair.

Entities:  

Mesh:

Year:  2009        PMID: 19629442     DOI: 10.1007/s00167-009-0871-4

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  40 in total

1.  Failure strength of repair devices versus meniscus suturing techniques.

Authors:  Mehmet Aşík; Nadir Sener
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2001-10-09       Impact factor: 4.342

2.  Meniscal repair devices.

Authors:  F A Barber; M A Herbert
Journal:  Arthroscopy       Date:  2000-09       Impact factor: 4.772

3.  Chondral injury following meniscal repair with a biodegradable implant.

Authors:  K Anderson; R G Marx; J Hannafin; R F Warren
Journal:  Arthroscopy       Date:  2000-10       Impact factor: 4.772

4.  Failure of a biodegradable meniscal arrow. A case report.

Authors:  M R Hutchinson; S A Ash
Journal:  Am J Sports Med       Date:  1999 Jan-Feb       Impact factor: 6.202

Review 5.  Complications in arthroscopic meniscal surgery.

Authors:  N C Small
Journal:  Clin Sports Med       Date:  1990-07       Impact factor: 2.182

6.  Stabilizing mechanisms of the loaded and unloaded knee joint.

Authors:  H H Hsieh; P S Walker
Journal:  J Bone Joint Surg Am       Date:  1976-01       Impact factor: 5.284

7.  Injury to the popliteal artery as a complication of arthroscopic surgery. A report of two cases.

Authors:  J T Jeffries; B J Gainor; W C Allen; D Cikrit
Journal:  J Bone Joint Surg Am       Date:  1987-06       Impact factor: 5.284

8.  Late degenerative changes after meniscectomy. Factors affecting the knee after operation.

Authors:  P R Allen; R A Denham; A V Swan
Journal:  J Bone Joint Surg Br       Date:  1984-11

9.  Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time. An in vitro experimental study.

Authors:  S P Arnoczky; M Lavagnino
Journal:  Am J Sports Med       Date:  2001 Mar-Apr       Impact factor: 6.202

10.  "All-inside" meniscal repair devices: an experimental study in the goat model.

Authors:  Mark D Miller; Alex J Kline; Kerry G Jepsen
Journal:  Am J Sports Med       Date:  2004-06       Impact factor: 6.202

View more
  11 in total

1.  Long-term outcome after all-inside meniscal repair using the RapidLoc system.

Authors:  Eirik Solheim; Janne Hegna; Eivind Inderhaug
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-14       Impact factor: 4.342

2.  The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus.

Authors:  Ashraf Abdelkafy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-12       Impact factor: 4.342

3.  Clinical results of arthroscopic all-inside lateral meniscal repair using the Meniscal Viper Repair System.

Authors:  Tetsuo Hagino; Satoshi Ochiai; Yoshiyuki Watanabe; Shinya Senga; Masanori Wako; Takashi Ando; Eiichi Sato; Hirotaka Haro
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-23

4.  What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Authors:  Francois Hardeman; Kristoff Corten; Michiel Mylle; Bert Van Herck; René Verdonk; Peter Verdonk; Johan Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-12       Impact factor: 4.342

Review 5.  Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

Authors:  Daniel M Buckland; Patrick Sadoghi; Matthias D Wimmer; Patrick Vavken; Geert I Pagenstert; Victor Valderrabano; Claudio Rosso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

6.  Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system.

Authors:  Mohamed Mahmoud Abouheif; Hayatoshi Shibuya; Takuya Niimoto; Wirat Kongcharoensombat; Masataka Deie; Nobuo Adachi; Mitsuo Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

7.  Long-term outcome after meniscal repair.

Authors:  Mike Tengrootenhuysen; Geert Meermans; Kathleen Pittoors; Roger van Riet; Jan Victor
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-10-15       Impact factor: 4.342

8.  Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears.

Authors:  Charles Milchteim; Eric A Branch; Ty Maughon; Jay Hughey; Adam W Anz
Journal:  Orthop J Sports Med       Date:  2016-04-08

9.  Increased Construct Stiffness With Meniscal Repair Sutures and Devices Increases the Risk of Cheese-Wiring During Biomechanical Load-to-Failure Testing.

Authors:  Sebastian Müller; Tanja Schwenk; Michael de Wild; Dimitris Dimitriou; Claudio Rosso
Journal:  Orthop J Sports Med       Date:  2021-06-15

10.  The Results of All-Inside Meniscus Repair Using the Viper Repair System Simultaneously with Anterior Cruciate Ligament Reconstruction.

Authors:  Hong Je Kang; Churl Hong Chun; Kwang Mee Kim; Hang Hwan Cho; Johnsel C Espinosa
Journal:  Clin Orthop Surg       Date:  2015-05-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.