Literature DB >> 12353275

Coronary MRA with 3D undersampled projection reconstruction TrueFISP.

Andrew C Larson1, Orlando P Simonetti, Debiao Li.   

Abstract

Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal-to-noise ratio (SNR) or streak artifact and the number of acquired k-space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k-space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three-dimensional (3D) PR TrueFISP for breathhold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24-heartbeat coronary imaging scheme, segmented 3D PR TrueFISP provided a 1.0 x 1.0 mm(2) isotropic in-plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in-plane voxel size within a single breathhold and is a promising technique for coronary artery imaging. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12353275     DOI: 10.1002/mrm.10262

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

Authors:  Behzad Sharif; Rohan Dharmakumar; Reza Arsanjani; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-17       Impact factor: 4.668

Review 3.  Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.

Authors:  Elmar Spuentrup; Rene M Botnar
Journal:  Eur Radiol       Date:  2005-08-25       Impact factor: 5.315

4.  Hybrid ultrasound MRI for improved cardiac imaging and real-time respiration control.

Authors:  David A Feinberg; Daniel Giese; D Andre Bongers; Sudhir Ramanna; Maxim Zaitsev; Michael Markl; Matthias Günther
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

5.  Contrast-kinetics-resolved whole-heart coronary MRA using 3DPR.

Authors:  Peng Lai; Feng Huang; Yu Li; Sonia Nielles-Vallespin; Xiaoming Bi; Renate Jerecic; Debiao Li
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

6.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T with radial EPI.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Magn Reson Med       Date:  2011-02-08       Impact factor: 4.668

7.  Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease.

Authors:  Richard M McCarthy; Vibhas S Deshpande; Nirat Beohar; Sheridan N Meyers; Steven M Shea; Jordin D Green; Xin Liu; Xiaoming Bi; F Scott Pereles; John Paul Finn; Charles J Davidson; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

8.  Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes.

Authors:  Na Zhang; Liqiu Zou; Yi Huang; Dexiang Liu; Yukuan Tang; Zhaoyang Fan; Hanwei Chen; Xin Liu
Journal:  PLoS One       Date:  2015-06-02       Impact factor: 3.240

Review 9.  Myocardial arterial spin labeling.

Authors:  Frank Kober; Terrence Jao; Thomas Troalen; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2016-04-12       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.