Myocardial tagging with 3D-CSPAMM.

Salome Ryf1, Marcus A Spiegel, Michael Gerber, Peter Boesiger.   

Abstract

PURPOSE: To introduce a true three-dimensional (3D) tagging technique for the assessment of myocardial tissue motion.
MATERIALS AND METHODS: To generate a 3D tagging grid, a complementary spatial modulation of magnetization (CSPAMM) was applied in three spatial directions. Imaging was performed using a conventional fast 3D gradient-echo sequence. For automatic analysis of the 3D-CSPAMM data set, evaluation software, based on a 3D extension of the HARP technique, was used.
RESULTS: Successful application of the 3D-CSPAMM technique in healthy subjects allowed the accurate determination of quantitative 3D motion patterns in the human heart.
CONCLUSION: 3D-CSPAMM may contribute to the quantification of the local 3D myocardial motion pattern throughout the cardiac cycle. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12205589     DOI: 10.1002/jmri.10145

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  27 in total

1.  Incompressible deformation estimation algorithm (IDEA) from tagged MR images.

Authors:  Xiaofeng Liu; Khaled Z Abd-Elmoniem; Maureen Stone; Emi Z Murano; Jiachen Zhuo; Rao P Gullapalli; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2011-09-19       Impact factor: 10.048

Review 2.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

3.  Left ventricular modelling: a quantitative functional assessment tool based on cardiac magnetic resonance imaging.

Authors:  C A Conti; E Votta; C Corsi; D De Marchi; G Tarroni; M Stevanella; M Lombardi; O Parodi; E G Caiani; A Redaelli
Journal:  Interface Focus       Date:  2011-03-23       Impact factor: 3.906

4.  Oblique 3D MRI tags for the estimation of true 3D cardiac motion parameters.

Authors:  Yu Shimizu; Akira Amano; Tetsuya Matsuda
Journal:  Int J Cardiovasc Imaging       Date:  2010-06-08       Impact factor: 2.357

5.  Cine and tagged magnetic resonance imaging in short-term stunned versus necrotic myocardium.

Authors:  Kai Uwe Juergens; Peter Reimer; Thomas Peter Weber; Bernd Tombach; Christoph Bremer; Bernhard Renger; Hugo Van Aken; Walter Heindel
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

6.  Magnetic resonance imaging of regional cardiac function in the mouse.

Authors:  E Heijman; G J Strijkers; J Habets; B Janssen; K Nicolay
Journal:  MAGMA       Date:  2004-12-20       Impact factor: 2.310

7.  Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value.

Authors:  Thorsten R C Johnson; Nicole Bayrhof; Armin Huber; Joost P A Kuijer; Roger Luechinger; Olaf Dietrich; Dietrich Stoevesandt; Dorthe Pedersen; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2007-04-19       Impact factor: 5.315

8.  A scale space based algorithm for automated segmentation of single shot tagged MRI of shearing deformation.

Authors:  Andre M J Sprengers; Matthan W A Caan; Kevin M Moerman; Aart J Nederveen; Rolf M Lamerichs; Jaap Stoker
Journal:  MAGMA       Date:  2012-08-15       Impact factor: 2.310

9.  Direct three-dimensional myocardial strain tensor quantification and tracking using zHARP.

Authors:  Khaled Z Abd-Elmoniem; Matthias Stuber; Jerry L Prince
Journal:  Med Image Anal       Date:  2008-04-15       Impact factor: 8.545

Review 10.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364