Literature DB >> 15614514

Magnetic resonance imaging of regional cardiac function in the mouse.

E Heijman1, G J Strijkers, J Habets, B Janssen, K Nicolay.   

Abstract

In this paper we introduce an improved harmonic phase (HARP) analysis for complementary spatial modulation of magnetization (CSPAMM) tagging of the mouse left ventricular wall, which enables the determination of regional displacement fields with the same resolution as the corresponding CINE anatomical images. CINE MRI was used to measure global function, such as the ejection fraction. The method was tested on two healthy mouse hearts and two mouse hearts with a myocardial infarction, which was induced by a ligation of the left anterior descending coronary artery. We show that the regional displacement fields can be determined. The mean circumferential strain for the left ventricular wall of one of the healthy mice was -0.09 +/- 0.04 (mean +/- standard deviation), while for one of the infarcted mouse hearts strains of -0.02 +/- 0.02 and -0.10 +/- 0.03 were found in the infarcted and remote regions, respectively.

Entities:  

Mesh:

Year:  2004        PMID: 15614514     DOI: 10.1007/s10334-004-0082-4

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  46 in total

Review 1.  Quantification in cardiac MRI.

Authors:  R J van der Geest; J H Reiber
Journal:  J Magn Reson Imaging       Date:  1999-11       Impact factor: 4.813

2.  Optimization of tag thickness for measuring position with magnetic resonance imaging.

Authors:  E Atalar; E R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

3.  In vivo metabolic imaging of cardiac bioenergetics in transgenic mice.

Authors:  E Omerovic; M Basetti; E Bollano; M Bohlooly-Y; M Bohlooly; J Törnell; J Isgaard; A Hjalmarson; B Soussi; F Waagstein
Journal:  Biochem Biophys Res Commun       Date:  2000-04-29       Impact factor: 3.575

Review 4.  Blood pool contrast agents for cardiovascular MR imaging.

Authors:  L J Kroft; A de Roos
Journal:  J Magn Reson Imaging       Date:  1999-09       Impact factor: 4.813

5.  Magnetic resonance imaging accurately estimates LV mass in a transgenic mouse model of cardiac hypertrophy.

Authors:  F Franco; S K Dubois; R M Peshock; R V Shohet
Journal:  Am J Physiol       Date:  1998-02

6.  Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia.

Authors:  A E Arai; C C Gaither; F H Epstein; R S Balaban; S D Wolff
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

7.  Measurement of left ventricular mass in vivo using gated nuclear magnetic resonance imaging.

Authors:  M S Florentine; C L Grosskreutz; W Chang; J A Hartnett; V D Dunn; J C Ehrhardt; S R Fleagle; S M Collins; M L Marcus; D J Skorton
Journal:  J Am Coll Cardiol       Date:  1986-07       Impact factor: 24.094

8.  Improved myocardial tagging contrast.

Authors:  S E Fischer; G C McKinnon; S E Maier; P Boesiger
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

Review 9.  Autonomic control of blood pressure in mice: basic physiology and effects of genetic modification.

Authors:  Ben J A Janssen; Jos F M Smits
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2002-06       Impact factor: 3.619

10.  In vivo time-resolved quantitative motion mapping of the murine myocardium with phase contrast MRI.

Authors:  Jörg U G Streif; Volker Herold; Michael Szimtenings; Titus E Lanz; Matthias Nahrendorf; Frank Wiesmann; Eberhard Rommel; Axel Haase
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

View more
  7 in total

Review 1.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

2.  Determination of three-dimensional ventricular strain distributions in gene-targeted mice using tagged MRI.

Authors:  Joyce S Chuang; Alice Zemljic-Harpf; Robert S Ross; Lawrence R Frank; Andrew D McCulloch; Jeffrey H Omens
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

3.  Global myocardial strain assessment by different imaging modalities to predict outcomes after ST-elevation myocardial infarction: A systematic review.

Authors:  Abhishek Shetye; Sheraz A Nazir; Iain B Squire; Gerald P McCann
Journal:  World J Cardiol       Date:  2015-12-26

4.  Comprehensive cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE.

Authors:  Xiaodong Zhong; Lauren B Gibberman; Bruce S Spottiswoode; Andrew D Gilliam; Craig H Meyer; Brent A French; Frederick H Epstein
Journal:  J Cardiovasc Magn Reson       Date:  2011-12-30       Impact factor: 5.364

5.  A practical approach to remote ischemic preconditioning and ischemic preconditioning against myocardial ischemia/reperfusion injury.

Authors:  Matthias Totzeck; Ulrike B Hendgen-Cotta; Brent A French; Tienush Rassaf
Journal:  J Biol Methods       Date:  2016-10-31

6.  Guidelines for measuring cardiac physiology in mice.

Authors:  Merry L Lindsey; Zamaneh Kassiri; Jitka A I Virag; Lisandra E de Castro Brás; Marielle Scherrer-Crosbie
Journal:  Am J Physiol Heart Circ Physiol       Date:  2018-01-05       Impact factor: 4.733

Review 7.  Molecular and Integrative Physiological Effects of Isoflurane Anesthesia: The Paradigm of Cardiovascular Studies in Rodents using Magnetic Resonance Imaging.

Authors:  Christakis Constantinides; Kathy Murphy
Journal:  Front Cardiovasc Med       Date:  2016-07-29
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.