Literature DB >> 12199574

A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection.

Ulli Backofen1, Frank-Michael Matysik, Craig E Lunte.   

Abstract

A simple capillary electrophoresis system in the planar format that uses a new, hydrodynamic injection principle is described. The system was realized with poly(dimethylsiloxane)-glass chips and microdisk electrodes for amperometric detection. Using a double-tee injector, no precise voltage control of the electrolyte reservoirs was needed, thus making the microchip CE system more user-friendly. The analytical characteristics of chip-based CE-EC were evaluated using ascorbic acid as the model analyte. The reproducibility of migration time and signal height was expressed by relative standard deviations of 1.2% and 5.1%, respectively (n = 5). The limit of detection for ascorbic acid was approximately 5 microM at a signal-to-noise ratio of 3. Practical application concerning the determination of physiologically relevant compounds such as noradrenaline and L-dopa are discussed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12199574      PMCID: PMC2519826          DOI: 10.1021/ac020110j

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Fabrication and evaluation of a carbon-based dual-electrode detector for poly(dimethylsiloxane) electrophoresis chips.

Authors:  A J Gawron; R S Martin; S M Lunte
Journal:  Electrophoresis       Date:  2001-01       Impact factor: 3.535

Review 2.  Fabrication of microfluidic systems in poly(dimethylsiloxane).

Authors:  J C McDonald; D C Duffy; J R Anderson; D T Chiu; H Wu; O J Schueller; G M Whitesides
Journal:  Electrophoresis       Date:  2000-01       Impact factor: 3.535

3.  Integrated system for rapid PCR-based DNA analysis in microfluidic devices.

Authors:  J Khandurina; T E McKnight; S C Jacobson; L C Waters; R S Foote; J M Ramsey
Journal:  Anal Chem       Date:  2000-07-01       Impact factor: 6.986

4.  A perfluorosulfonated ionomer end-column electrical decoupler for capillary electrophoresis/electrochemical detection.

Authors:  S Park; C E Lunte
Journal:  Anal Chem       Date:  1995-12-01       Impact factor: 6.986

5.  Integrated electrophoresis chips/amperometric detection with sputtered gold working electrodes.

Authors:  J Wang; B Tian; E Sahlin
Journal:  Anal Chem       Date:  1999-09-01       Impact factor: 6.986

6.  Capillary electrophoresis chips with integrated electrochemical detection.

Authors:  A T Woolley; K Lao; A N Glazer; R A Mathies
Journal:  Anal Chem       Date:  1998-02-15       Impact factor: 6.986

7.  Determination of cannabinoids in hair using high-pH* non-aqueous electrolytes and electrochemical detection. Some aspects of sensitivity and selectivity.

Authors:  Ulli Backofen; Frank-Michael Matysik; Craig E Lunte
Journal:  J Chromatogr A       Date:  2002-01-04       Impact factor: 4.759

8.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

9.  Separation and detection of explosives on a microchip using micellar electrokinetic chromatography and indirect laser-induced fluorescence

Authors: 
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

10.  Microfabricated electrophoresis chips for simultaneous bioassays of glucose, uric acid, ascorbic acid, and acetaminophen.

Authors:  J Wang; M P Chatrathi; B Tian; R Polsky
Journal:  Anal Chem       Date:  2000-06-01       Impact factor: 6.986

View more
  6 in total

1.  Study of injection bias in a simple hydrodynamic injection in microchip CE.

Authors:  Maojun Gong; Kenneth R Wehmeyer; Apryll M Stalcup; Patrick A Limbach; William R Heineman
Journal:  Electrophoresis       Date:  2007-05       Impact factor: 3.535

2.  Collection, focusing, and metering of DNA in microchannels using addressable electrode arrays for portable low-power bioanalysis.

Authors:  Faisal A Shaikh; Victor M Ugaz
Journal:  Proc Natl Acad Sci U S A       Date:  2006-03-21       Impact factor: 11.205

3.  Integrated membrane filters for minimizing hydrodynamic flow and filtering in microfluidic devices.

Authors:  Scott D Noblitt; James R Kraly; Jaimie M VanBuren; Susanne V Hering; Jeffrey L Collett; Charles S Henry
Journal:  Anal Chem       Date:  2007-07-18       Impact factor: 6.986

4.  Soft lithography for micro- and nanoscale patterning.

Authors:  Dong Qin; Younan Xia; George M Whitesides
Journal:  Nat Protoc       Date:  2010-02-18       Impact factor: 13.491

5.  Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization.

Authors:  Xuefei Sun; Ryan T Kelly; William F Danielson; Nitin Agrawal; Keqi Tang; Richard D Smith
Journal:  Electrophoresis       Date:  2011-04-26       Impact factor: 3.535

6.  Recent Advances in Microscale Western Blotting.

Authors:  Brittany J Sanders; Daniel C Kim; Robert C Dunn
Journal:  Anal Methods       Date:  2016-09-15       Impact factor: 2.896

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.