Literature DB >> 12195062

Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques.

Marcus Richter1, René Schmidt, Lutz Claes, Wolfhart Puhl, Hans-Joachim Wilke.   

Abstract

STUDY
DESIGN: Six different techniques for atlantoaxial fixation were biomechanically compared in vitro by nondestructive testing.
OBJECTIVE: To evaluate the immediate three-dimensional stability of a new atlas claw combined with transarticular screws and alternative techniques for transarticular screw fixation in comparison with established techniques. SUMMARY OF BACKGROUND DATA: Posterior transarticular screw fixation in combination with wire-bone graft constructs is frequently used for C1-C2 fixation. Sublaminar wire passage carries the potential risk of neurologic complication. Transarticular screw fixation is technically demanding and, for anatomic reasons, not always feasible.
METHODS: Six human cervical specimens were loaded nondestructively with pure moments, and unconstrained motion at C1-C2 was measured. The six specimens were instrumented with each of the following fixation techniques: Gallie fixation, transarticular screws and Gallie fixation, transarticular screws, transarticular screws and a new atlas claw, isthmic screws in the axis and the atlas claw, and lateral mass screws in the atlas and isthmic screws in the axis connected with rods.
RESULTS: The transarticular screws restricted lateral bending and axial rotation best. The three-point fixations (transarticular + Gallie and transarticular + claw) additionally restricted flexion-extension, with lowest values for transarticular screws and the atlas claw. The alternative techniques were not as stable as the three-point fixations, but more stable than the Gallie fixation.
CONCLUSIONS: Biomechanically, the three-point fixation with transarticular screws and the atlas claw provides a rigid internal fixation that is not dependent on bone graft and sublaminar wiring. In cases wherein transarticular screws are not feasible, the isthmic screws and claw or the lateral mass screws and isthmic screws are biomechanical alternatives with less immediate stability.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12195062     DOI: 10.1097/00007632-200208150-00008

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  35 in total

1.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

2.  Effect of constrained posterior screw and rod systems for primary stability: biomechanical in vitro comparison of various instrumentations in a single-level corpectomy model.

Authors:  René Schmidt; Hans-Joachim Wilke; Lutz Claes; Wolfhart Puhl; Marcus Richter
Journal:  Eur Spine J       Date:  2004-07-10       Impact factor: 3.134

3.  Clinical application of C2 laminar screw technique.

Authors:  Weihu Ma; Leling Feng; Rongming Xu; Xiaochen Liu; Alan H Lee; Shaohua Sun; Liujun Zhao; Yong Hu; Guanyi Liu
Journal:  Eur Spine J       Date:  2010-06-05       Impact factor: 3.134

4.  Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study.

Authors:  Jan Bredow; Carolin Meyer; Max Joseph Scheyerer; Florian Siedek; Lars Peter Müller; Peer Eysel; Gregor Stein
Journal:  Eur Spine J       Date:  2016-01-25       Impact factor: 3.134

5.  Biomechanical comparison of transfacet screws to lateral mass screw-rod constructs in the lower cervical spine.

Authors:  Jie Tong; Wei Ji; Ruozhou Zhou; Zhiping Huang; Sheting Liu; Qingan Zhu
Journal:  Eur Spine J       Date:  2015-11-03       Impact factor: 3.134

6.  Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results.

Authors:  Heiko Koller; Volker Kammermeier; Dietmar Ulbricht; Allan Assuncao; Stefan Karolus; Boris van den Berg; Ulrich Holz
Journal:  Eur Spine J       Date:  2006-04-08       Impact factor: 3.134

7.  Minimally invasive anterior transarticular screw fixation and microendoscopic bone graft for atlantoaxial instability.

Authors:  Jian Wang; Yue Zhou; ZhengFeng Zhang; ChangQing Li; WenJie Zheng; Yuan Zhang
Journal:  Eur Spine J       Date:  2012-08       Impact factor: 3.134

8.  C1-C2 arthrodesis after transoral odontoidectomy and suboccipital craniectomy for ventral brain stem compression in Chiari I patients.

Authors:  Steven W Hwang; Carl B Heilman; Ron I Riesenburger; James Kryzanski
Journal:  Eur Spine J       Date:  2008-07-16       Impact factor: 3.134

9.  [Surgery of the cervical spine in rheumatoid arthritis. Diagnostics and indication].

Authors:  B Cakir; W Käfer; H Reichel; R Schmidt
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

10.  Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study.

Authors:  Florian Fensky; Rebecca A Kueny; Kay Sellenschloh; Klaus Püschel; Michael M Morlock; Johannes M Rueger; Wolfgang Lehmann; Gerd Huber; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2013-12-31       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.