Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model.

Charles R Bragdon1, Henrik Malchau, Xunhua Yuan, Rebecca Perinchief, Johan Kärrholm, Niclas Börlin, Daniel M Estok, William H Harris.   

Abstract

The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12168656     DOI: 10.1016/S0736-0266(01)00171-1

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  30 in total

1.  Precision and accuracy measurement of radiostereometric analysis applied to movement of the sacroiliac joint.

Authors:  Thomas J Kibsgård; Olav Røise; Britt Stuge; Stephan M Röhrl
Journal:  Clin Orthop Relat Res       Date:  2012-06-14       Impact factor: 4.176

2.  Continued improved wear with an annealed highly cross-linked polyethylene.

Authors:  William N Capello; James A D'Antonio; Rama Ramakrishnan; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2010-09-16       Impact factor: 4.176

3.  Emerging ideas: soft tissue applications of radiostereometric analysis.

Authors:  Lucian B Solomon; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2010-11-23       Impact factor: 4.176

4.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

5.  Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Nucl Instrum Methods Phys Res B       Date:  2007-12       Impact factor: 1.377

6.  Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty.

Authors:  A J Graydon; S Malak; I A Anderson; R P Pitto
Journal:  Int Orthop       Date:  2008-05-28       Impact factor: 3.075

7.  The Elite-Plus stem migrates more than the flanged Charnley stem.

Authors:  Thord von Schewelov; Lennart Sanzén; Jack Besjakov; Ake Carlsson
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

8.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

9.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

10.  Notes on the use and interpretation of radiostereometric analysis.

Authors:  Brian Derbyshire; Robin J Prescott; Martyn L Porter
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.