Literature DB >> 12168654

Fatigue crack growth rate does not depend on mantle thickness: an idealized cemented stem construct under torsional loading.

Justin Hertzler1, Mark A Miller, Kenneth A Mann.   

Abstract

Retrieval studies indicate that cemented stem loosening in femoral components of total hip replacement can initiate at the stem-cement interface. The etiology of the crack propagation process from the stem-cement interface is not well understood, but cracks are typically associated with thin cement mantles. In this study, a combination of experimental and computational methods was used to investigate the fatigue crack propagation process from the stem-PMMA cement interface using a novel torsional loading model. Constructs with thin (1 mm), medium (3 mm) or thick (7 mm) cement mantles were evaluated. Crack growth was stable for all cases and the rate of crack growth diminished with increasing crack length. Crack growth rate did not depend on mantle thickness (p > 0.05) over the first 1 mm of crack length, but cracks in thin mantles reached the full thickness of the mantle in the fewest number of loading cycles. The fracture mechanics-based finite element models indicated decreased stress intensity factors with increasing crack length and were consistent with the experimental findings. When combined with a fatigue crack growth Paris-law for PMMA cement, the finite element models provided reasonable predictions of the crack growth process.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12168654     DOI: 10.1016/S0736-0266(02)00004-9

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  6 in total

1.  The behavior of the micro-mechanical cement-bone interface affects the cement failure in total hip replacement.

Authors:  Daan Waanders; Dennis Janssen; Kenneth A Mann; Nico Verdonschot
Journal:  J Biomech       Date:  2010-10-30       Impact factor: 2.712

2.  Fatigue debonding of the roughened stem-cement interface: effects of surface roughness and stem heating conditions.

Authors:  Leatha A Damron; Do-Gyoon Kim; Kenneth A Mann
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-07       Impact factor: 3.368

3.  Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.

Authors:  Kenneth A Mann; Leatha A Damron; Mark A Miller; Amos Race; Michael T Clarke; Richard J Cleary
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

4.  Three-dimensional shape optimization of a cemented hip stem and experimental validations.

Authors:  Masaru Higa; Hiromasa Tanino; Ikuya Nishimura; Yoshinori Mitamura; Takeo Matsuno; Hiroshi Ito
Journal:  J Artif Organs       Date:  2014-10-16       Impact factor: 1.731

5.  A modified PMMA cement (Sub-cement) for accelerated fatigue testing of cemented implant constructs using cadaveric bone.

Authors:  Amos Race; Mark A Miller; Kenneth A Mann
Journal:  J Biomech       Date:  2008-09-05       Impact factor: 2.712

6.  Study of an Additional Layer of Cement Mantle Hip Joints for Reducing Cracks.

Authors:  J Jamari; Eko Saputra; Iwan Budiwan Anwar; Emile van der Heide
Journal:  J Funct Biomater       Date:  2019-09-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.