Literature DB >> 18774136

A modified PMMA cement (Sub-cement) for accelerated fatigue testing of cemented implant constructs using cadaveric bone.

Amos Race1, Mark A Miller, Kenneth A Mann.   

Abstract

Pre-clinical screening of cemented implant systems could be improved by modeling the longer-term response of the implant/cement/bone construct to cyclic loading. We formulated bone cement with degraded fatigue fracture properties (Sub-cement) such that long-term fatigue could be simulated in short-term cadaver tests. Sub-cement was made by adding a chain-transfer agent to standard polymethylmethacrylate (PMMA) cement. This reduced the molecular weight of the inter-bead matrix without changing reaction-rate or handling characteristics. Static mechanical properties were approximately equivalent to normal cement. Over a physiologically reasonable range of stress-intensity factor, fatigue crack propagation rates for Sub-cement were higher by a factor of 25+/-19. When tested in a simplified 2 1/2-D physical model of a stem-cement-bone system, crack growth from the stem was accelerated by a factor of 100. Sub-cement accelerated both crack initiation and growth rate. Sub-cement is now being evaluated in full stem/cement/femur models.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18774136      PMCID: PMC2612580          DOI: 10.1016/j.jbiomech.2008.07.016

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  25 in total

1.  Innovation in total hip replacement--when is new better?

Authors:  P S Walker
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

2.  Discriminating the loosening behaviour of cemented hip prostheses using measurements of migration and inducible displacement.

Authors:  S A Maher; P J Prendergast
Journal:  J Biomech       Date:  2002-02       Impact factor: 2.712

3.  Hip-joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction.

Authors:  J Stolk; N Verdonschot; R Huiskes
Journal:  J Biomech       Date:  2001-07       Impact factor: 2.712

4.  Residual stress due to curing can initiate damage in porous bone cement: experimental and theoretical evidence.

Authors:  A B Lennon; P J Prendergast
Journal:  J Biomech       Date:  2002-03       Impact factor: 2.712

5.  Can finite element models detect clinically inferior cemented hip implants?

Authors:  Jan Stolk; Suzanne A Maher; Nico Verdonschot; Patrick J Prendergast; Rik Huiskes
Journal:  Clin Orthop Relat Res       Date:  2003-04       Impact factor: 4.176

6.  The influence of surface roughness on stem-cement gaps.

Authors:  A Race; M A Miller; D C Ayers; R J Cleary; K A Mann
Journal:  J Bone Joint Surg Br       Date:  2002-11

7.  Comparative in vitro study on the long term performance of cemented hip stems: validation of a protocol to discriminate between "good" and "bad" designs.

Authors:  Luca Cristofolini; Amelia Saponara Teutonico; Luisa Monti; Angelo Cappello; Aldo Toni
Journal:  J Biomech       Date:  2003-11       Impact factor: 2.712

8.  Fracture and fatigue properties of acrylic bone cement: the effects of mixing method, sterilization treatment, and molecular weight.

Authors:  J Graham; L Pruitt; M Ries; N Gundiah
Journal:  J Arthroplasty       Date:  2000-12       Impact factor: 4.757

9.  Fatigue crack growth rate does not depend on mantle thickness: an idealized cemented stem construct under torsional loading.

Authors:  Justin Hertzler; Mark A Miller; Kenneth A Mann
Journal:  J Orthop Res       Date:  2002-07       Impact factor: 3.494

10.  Fatigue crack propagation rates in PMMA bone cement cannot be reduced to a single power law.

Authors:  Amos Race; Kenneth A Mann
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-07       Impact factor: 3.368

View more
  1 in total

1.  Using 'subcement' to simulate the long-term fatigue response of cemented femoral stems in a cadaver model: could a novel preclinical screening test have caught the Exeter matt problem?

Authors:  A Race; M A Miller; K A Mann
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.