Literature DB >> 12166709

Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures.

E Hofmann1, M Behr, G Handel.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the frequency of technical failure rates and the maintenance costs of clasp- or double crown-retained removable partial dentures (RPDs) (parallel-sided and conical double crowns).
MATERIAL AND METHODS: According to three different retainer systems used between January 1992 to December 1998, three subgroups were randomly assigned from a group of 181 patients consisting of forty cases each. The average observation time was 4.2+/-1.7 years, with a minimum of 1.0 years and a maximum of 6.9 years. Technical complications such as fractures of the artificial teeth, loss of cementation, loss of facings as well as fractures of the metal framework and the soldering were recorded due to the medical reports.
RESULTS: Twenty percent of all clasp-retained dentures showed technical complications during the observation period, whereas 50% of conical crown-retained (CC) and 32.5% of the parallel-sided retained dentures (PS) required repair. Most often reported was loss of cementation for double crowns (n=13, 32.5% PS; n=8, 20% CC) and fractures of the clasps (n=5). Although clasp-retained dentures had a markedly lower frequency of failures (n=8) than double crown systems (n=31), the calculated repair costs per event during the observation time were more than twice as high for clasp-retained dentures (172.5 Euro) than for double crown systems (8-78 Euro). The hypothesis that the maintenance costs of the more sophisticated double crown system are higher must be rejected.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12166709     DOI: 10.1007/s00784-002-0160-9

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  9 in total

1.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

2.  Wear behavior of different double-crown systems.

Authors:  Jörg Engels; Oliver Schubert; Jan-Frederik Güth; Matthias Hoffmann; Christian Jauernig; Kurt Erdelt; Michael Stimmelmayr; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-05-10       Impact factor: 3.573

3.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

4.  Case-control study on the survival of abutment teeth of partially dentate patients.

Authors:  K Stegelmann; M Dirheimer; E Ludwig; O Moldovan; H Rudolph; R G Luthardt; B A Just
Journal:  Clin Oral Investig       Date:  2011-12-28       Impact factor: 3.573

5.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

6.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

7.  Rehabilitation of a maxillectomy case with telescopic crowns: a case report.

Authors:  Anil Kumar Sethuram; Nandkishore Sahoo; Hs Sandhu; Vijayanathan Radhakrishnan
Journal:  J Indian Prosthodont Soc       Date:  2012-07-10

8.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

Review 9.  Telescopic Denture.

Authors:  Mohammad Ayham Hakkoum; Ghassan Wazir
Journal:  Open Dent J       Date:  2018-03-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.